Permit Number: T20CM02674
Parcel: 110055140

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM02674
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2020 MARTIN BROWN FIRE REVIEW Approved
05/06/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The replacement faucets for the lavatories shall be metering faucets. The metering faucets shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.11, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09
05/06/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Verify the exhaust flow rate in the modified men's restroom. Ventilation for restrooms in public spaces requires a minimum of 50 CFM of mechanical exhaust per water closet or urinal if the exhaust is continuous and 70 CFM if the exhaust is intermittent. Reference: footnote e, Table 403.3.1.1, IMC 2018. Note that if HVAC air is supplied to the restroom, the exhaust is required to be continuous while the suite is occupied.
05/06/2020 ROBERT SHERRY WATER REVIEW Completed
05/19/2020 JOHN VAN WINKLE ENGINEERING REVIEW Passed
05/20/2020 ALEXANDRA HINES ZONING REVIEW Approved
05/20/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please provide full compliance with the 2018 IECC for the lighting.
05/20/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
05/20/2020 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed