| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide the BTU demand of each appliance, total demand, and total developed length from meter to the most remote appliance on the system, and verify the size of the supply pipe for the connected demand, G2413.3 & Table G2413.4(1). RESUBMIT WITH THE CORRECT DEVELOPED LENGTH. REMOVE THE RANGE BRANCH OR SHOW A 1" PIPE FROM THE METER TO FIRST BRANCH TEE. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/24/2020 | ANY | REJECT SHELF | RECEIVED |