Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM02351
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/15/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 05/15/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/18/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/18/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 05/28/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 05/29/2020 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 06/09/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 06/26/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A1.0 (Second Floor Plan); Sheet A8.0 (Enlarged Plan 6): The enlarged plan indicates the Fifth Floor Coffee Station, while the Second Floor Plan indicates this Coffee Station. Please clarify. 2. Sheet A1.0; Second Floor Plan: The east walls of spaces 218, 219, 220, 221, 222, and 223 are glass walls. Please reference Sheet A5.0 for the elevations of these walls. 3. Sheet A1.0; Second Floor Plan: The north wall of spaces 208, 209, and 210, and the south wall of space 202 are glass walls, but indicate in the Room Finish Schedule (Sheet A6.0) they are painted. Please verify. 4. Sheet A5.1; Enlarged Plan 1: Elevations 2, 3, 4, and 5 on the enlarged plan reference Sheet A9.0. Please revise that reference. 5. Sheet A5.1; Elevations 2 and 4: A note on these elevations references Sheet A9.0. Please revise that reference. 6. Sheet A7.0; Enlarged Plan 1: Elevations 2, 3, and 4 on the enlarged plan reference Sheet A8.17. Please revise that reference. 7. Sheet A8.0; Enlarged Plan 6: An elevation on the enlarged plan references Sheet A8.16. Please revise that reference. 8. Sheet A8.0; Enlarged Plan 1: Elevations 2, 3, 4, and 5 on the enlarged plan reference Sheet A8.16. Please revise that reference. 9. Sheets AV-1.0, AV-2.0, ID1.0, and ID2.0: These sheets are not stamped by a registered professional and lack a title block. Please revise. 10. General: Please provide written responses to all review comments. |
| 06/26/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |