Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM02224
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/14/2020 | ELISA HAMBLIN | ZONING | REVIEW | Approved | |
04/14/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
04/14/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | To large to walk thru. Please submit. |
04/14/2020 | EHAMBLI1 | ENGINEERING | REVIEW | Passed | |
04/14/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet S1.0; General Structural Notes (Note 1): This note indicates that work shall conform to the 2012 International Building Code. Please revise that code. 2. Sheet a1.0 (Floor Plan); Sheet a9.0 (Wall Types): On the east side of Doors 100 and 102, a Wall Type TL is indicated. That Wall Type is not indicated on Sheet a9.0. Please verify. 3. Sheet a1.0; Floor Plan: Two shafts at the south end of Cath Lab 1 and 2 indicate an FX Wall Type. Should these walls be fire resistance rated walls per the IBC Section 713? Please verify. 4. Sheet a1.0; Floor Plan: Two shafts at the north end of Cath Lab 1 and 2 indicate an FX Wall Type. Should these walls be fire resistance rated walls per the IBC Section 713? Please verify. 5. Sheet a1.0; Floor Plan: One shaft at the southwest corner of Cath Lab 2 indicates FX and X Wall Types. Should these walls be fire resistance rated walls per the IBC Section 713? Please verify. 6. Sheet a7.0; Restroom Grab Bars: Please include on this sheet the dimensional location of the grab bars per the ICC/ANSI Figures 604.5.1 and 604.5.2. 7. General: Please provide a Special Inspection Certificate with Parts A and B completed. This may be found at www.tucsonaz.gov/PDSD. 8. General: Please provide written responses to all review commentsl |
04/14/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/14/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Verify that the distance from the hot water source to the hot water termination for the public lavatory complies with the requirements of Section C404.5, IECC 2018. |
04/14/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
04/20/2020 | MARTIN BROWN | FIRE | REVIEW | Approved |