Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM02094
Parcel: 136380670

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM02094
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM02094
4111 S. Snapdragon St.
Detached Garage
Residential (1st Review)

TRANSMITTAL DATE: April 16, 2020

The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. The site plan shall be drawn at an Engineering scale, i.e. 1" = 10'.

2. Provide the zoning for the surrounding parcels on the site plan.

3. Provide a dimension from the center line of Snapdragon St. to the curb and a dimension from the curb to the street property line.

4. Provide a lot coverage calculation on the plan.

The proposed perimeter yard setbacks shown do not meet the minimum required. Per Unified Development Code (UDC) TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES the required perimeter yard setback is 6'-0" to the northeast and northwest is 6'-0". As this is an accessory structure per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). That all said you can request a setback waiver from your neighbors located at 4101 S SNAPDRAGON ST & 4102 S AZALEA ST. The following statement must be provided on you plot plan, one for each neighbor "My Name is __________________and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed 3'-0" from the property line as depicted on the site plan.

5. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/16/2020 SSHIELD1 ENGINEERING REVIEW Passed
04/16/2020 SSHIELD1 NPPO REVIEW Passed
05/04/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
04/02/2020 ANY REJECT SHELF RECEIVED