Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM01914
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/17/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM01914 6651 E Calle Herculo St Dining Room & Garage Addition Residential (1st Review) TRANSMITTAL DATE: April 17, 2020 The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. The site plan shall be drawn at an Engineering scale, i.e. 1" = 10'. 2. This plan is not to scale. If the 105' dimension for the north/south property lines is used to calibrate for measurement than the northern property line is approximately 82' versus 75' and the southern is 91' versus 83.8' 3. Remove the setback lines called out under Site Note 2 and provide setback dimensions from the proposed additions to the applicable property lines 4. Provide a dimension from the center line of Calle Herculo street to the curb and a dimension from the curb to the street property line. 5. Provide a lot coverage calculation on the plan that meets the requirements of Unified Development Code (UDC) Article 6.4.3. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 04/17/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 04/21/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Replace under sized beams with 3-1/8 x 12 GLB; provide gas demand & total length for determining diameter; show arc-fault breakers for new circuits. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/23/2020 | AHINES2 | OUT TO CUSTOMER | Completed |