Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T20CM01813
Parcel: 136174110

Review Status: Active

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T20CM01813
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change The 1" gas pipe supply a total 249,000 BTU at a TDL of 67' is undersized, Table G2413.4(1). Change to 1-1/4" or show separate branch lines from the meter to each appliance.

Ken Van Karsen
837-4912

Final Status

Task End Date Reviewer's Name Type of Review Description
03/21/2020 ANY REJECT SHELF RECEIVED