Permit Number: T20CM01769
Parcel: 13418113B

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - COMM

Permit Number - T20CM01769
Review Name: PLANS OK TO SUBMIT - COMM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: 7444 E Broadway Blvd - Residential Care Services - Unlimited
T20CM01769
Building plan.

TRANSMITTAL DATE: March 20, 2020

The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal.

1. Under "GENERAL ZONING ANALYSIS" provide the proposed use. This use should be Residential Care Services, Adult Care or Physical and Behavioral Health Services: Unlimited # of Residents subject to Use Specific Standards 4.9.7.J.3.d, .4, & .8 and 4.9.13.O.

2. Per UDC 7.9.7.J.8 The maximum permitted lot coverage is 60%. The minimum required setback from all interior lot lines adjoining residential zoning is 20 feet. The minimum required lot size is one and one-half acres, with the following exception. Exception: There is no minimum lot size requirement for Residential Care Services uses in the R-3, C-1, C-2, C-3, OCR-1, and OCR-2 zones. Provide a lot coverage calculation on the plan, see UDC Article 6.4.3.

3. As a note, provide calculations on the number of vehicle parking spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled.

4. The accessible vehicle parking spaces shown on sheet A1.11 do not appear to meet the requirements of 2018 IBC Chapter 11 and the ICC A117.1-2009. Although it is not a requirement to upgrade the accessible vehicle parking spaces it is strongly recommended.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
03/23/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Needs Review