Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T20CM01716
Parcel: 14039041C

Address:
5451 E BENSON HY

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM01716
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2020 DJELLEN1 ZONING REVIEW Approved
03/16/2020 DJELLEN1 ENGINEERING REVIEW Passed
03/16/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
03/16/2020 RMCCOY1 BUILDING-COMMERCIAL REVIEW Approved
03/16/2020 RMCCOY1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/19/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change The use of the bar area has changed from being a waiting room. Verify that the ventilation of the area is sufficient for the new use. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3.1.1, IMC 2018 or an approved engineering analysis of the specific occupancy type. Reference: Section 403.3.1.1, IMC 2018.
03/19/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Appliances (e.g. beverage dispensers, ice makers, etc.) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Section 608.14.1, IPC 2018 require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 608.1 and 608.3, IPC 2018.
03/19/2020 ROBERT SHERRY WATER REVIEW Completed
04/16/2020 MARTIN BROWN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/16/2020 LBOWERS1 OUT TO CUSTOMER Completed