Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM01593
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/21/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide a roof framing plan showing the beam size with fastening detail for carrying the live and dead weight. All wall openings are required for maintaining the carport design. An enclosed garage would require removing the dwelling window. |
04/29/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM01593 9201 E Creek St Carport Extension Residential (2nd Review) TRANSMITTAL DATE: April 29, 2020 The carport extension plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. The site plan shall be drawn at an engineering scale, i.e. 1" = 10' 2. The lot coverage calculation does not appear to be correct. Per UDC Article 6.4.3.B.3.b the shed should be included and the pool is not included. 3. Provide a street perimeter yard setback from the proposed carport addition to the street property line along Creek St. The minimum street perimeter yard setback is 20'-0" 4. Per UDC 6.4.5.C.1.b Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet. That said the street perimeter yard setback shown from the proposed carport addition to the street property line along Hearthstone Dr is required to be 10'-0", proposed is 4'-8" a Design Development Option (DDO) will need to be processed and approved prior to approval of this plan. You can find the DDO application packet at https://www.tucsonaz.gov/files/pdsd/2019_DDO_for_Setback_and_Height_UDC.pdf 5. The street dimensions shown are not correct. Creek Street dimension from the centerline of the street to the face of curb is 19'-0", dimension from face of curb to property line is 11'-0". Hearthstone Dr. dimension from the centerline of the street to the face of curb is 24'-0", dimension from face of curb to property line is 21'-0". 6. Remove all of the neighbor signoffs from the plan as they are applicable to this project. 7. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |