Permit Number: T20CM01349
Parcel: 12007338A

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM

Permit Number - T20CM01349
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2020 LSHAMIS1 ZONING REVIEW Reqs Change FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T20CM01349
SFR Porch, Bdrm and bath Addition (1st Review)
3908 S Liberty Av.

TRANSMITTAL DATE: March 4, 2020

DUE DATE: March 13, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

01.COMMENT: Per UDC Article 6.3-2.A, the perimeter yard setback needs to be 6' or 2/3 the height of the structure, apply the greater dimension. The setbacks to the West and the South are insufficient per UDC. Consider a Design Development Option (DDO), UDC Article 3.11.1, in order to proceed with this proposal, as is. The application can be found online here https://www.tucsonaz.gov/files/pdsd/forms/2014_Appeal_of_DDO_for_Applicant_UDC.pdf

02.COMMENT: Per UDC, Article 6.4.5.C, Street Perimeter Yard, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall, measured from the street property line, whichever is greater. Consider a Design Development Option (DDO) in order to proceed with this proposal, as is. https://www.tucsonaz.gov/files/pdsd/forms/2014_Appeal_of_DDO_for_Applicant_UDC.pdf

FOLLOW UP TO COMMENTS 1 AND 2: Only one DDO application is required for all 3 setback reduction proposals.

03.COMMENT: Address the structure on the Southwest corner of the property.

04.COMMENT: Provide setback dimensions from property line to all sides of the additional structures (i.e. addition #2 on the North side).

05.COMMENT: Fully dimension the existing structure on the indicated Floor Plan.

06.COMMENT: Clearly define and dimension the vehicular use area.

If you have any questions about this transmittal, Contact Loran Shamis by email Loran.Shamis@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
03/04/2020 LSHAMIS1 ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Loran Shamis
Planner

PROJECT: T20CM01349
3908 S Liberty Av
SFR Add 2 bedrooms/bathrooms and porch

TRANSMITTAL: March 17, 2020
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet facing each interior property line (Table 6.3-2.A).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet (UDC 6.4.5.C.1.a).

The applicant is proposing a three (3) foot building setback from the west and south interior property line and a 12 foot building setback from the east street property line.

Loran Shamis
loran.shamis@tucsonaz.gov
03/10/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set for review. See https://www.tucsonaz.gov/files/integrated-planning/PDSD/Fill_-_Residential_Submittal_Requirements_January_2020_1.pdf

K E Van Karsen
520 837-4912
03/17/2020 LSHAMIS1 NPPO REVIEW Passed
03/17/2020 LSHAMIS1 ENGINEERING REVIEW Passed