Permit Number: T20CM01096
Parcel: 133132030

Address:
7666 E HELEN ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T20CM01096
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/18/2020 JOHN VAN WINKLE ENGINEERING REVIEW Passed
02/24/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM01096
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the location of proposed structure and show the distance from property line, R106.1.1.

SECTIONS - DETAILS:

1. Show a cross-section detail of fasteners, R106.1.1.
2. Show the beam size, R301.
3. Show the minimum 12" footing depth below the undisturbed ground surface with two #4 rebar each wall at 3" above the bottom, R403.1.
4. Show a post base with minimum ½" diameter anchor bolt, R403.1.6.
5. Specify all ledgers, Figure R606.11 (1) with fasteners, or H2.5 connection to the load bearing wall top plate.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
03/04/2020 IMONSHI1 ZONING REVIEW Reqs Change FROM: Iman Monshizadeh
PDSD Zoning Review Section

PROJECT: T20CM01096
Porch Addition (1st Review)
7666 E HELEN ST

TRANSMITTAL DATE: March 4th, 2020

DUE DATE: March 16th, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: A residential plot plan is required for this addition. A sample of a plot plan with the requirements can be found at
https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

If you have any questions feel free to come in to our counter for help Monday to Friday 8-1 at Public Works Building - 201 North Stone Avenue


If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.monshizadeh@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
03/04/2020 IMONSHI1 NPPO REVIEW Passed