Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM01061
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2020 | IMONSHI1 | ENGINEERING | REVIEW | Needs Review | |
| 02/25/2020 | TWEIDEM1 | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 02/25/2020 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: David Rivera Zoning review Section PROJECT: T20CM01061 - Proposed Solar Panel Canopy TRANSMITTAL: February 27, 2020 COMMENTS: The following comments are relative to an application for a Solar Canopy Structure within the side street perimeter yard 1. COMMENT: The plans for the proposed solar canopy have been reviewed by zoning but cannot approve the permit application at this time. Please address the following comments. 2. COMMENT: Clarify if the canopy is to be attached to the existing dwelling? If so provide details for the attachment on the cross section details on sheet S-1.0 3. COMMENT: After viewing the available documentation for the Belvedere street right of way, it has been found that the site drawing has not been drawn correctly and must be revised. The property line per COT plan I-574 sheet 22, the property line is fifteen feet from the face of the curb. The solar site plat depicts the property line at the curb which is incorrect. The site plan shall be revised to accurately depict the property lines and curb location for both Poe Street and Belvedere Avenue with the dimensions from curb to property lines labeled. 4. COMMENT: The proposed location of the canopy whether attached or detached must be setback from the actual property line ten feet. Until the corrected plot plan is included in the solar panel application additional comments for the DDO cannot be provided. Once the plot plan is corrected and the plans re-submitted for review Zoning can provide the applicant with comments to process a DDO for review and hopefully an approval. 5. COMMENT: Assure that the canopy cross section detail drawing on sheet 22 is labeled with the overall height of the canopy structure. If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/11/2020 | TWEIDEM1 | APPROVAL SHELF | Completed |
| 03/11/2020 | TWEIDEM1 | OUT TO CUSTOMER | Completed |
| 03/11/2020 | TWEIDEM1 | REJECT SHELF | Completed |