Permit Number: T20CM01053
Parcel: 134170310

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM01053
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/18/2020 LSHAMIS1 ZONING REVIEW Reqs Change FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T20CM01053
SFR Storage Addition (1st Review)
7310 E Princeton Dr.

TRANSMITTAL DATE: 2/18/20

DUE DATE: 2/27/20

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

01. COMMENT: The requirements and an example of a residential plot plan can be found here https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

02. COMMENT: Dimensional Standards can be accessed in the City of Tucson, Unified Development Code (UDC) Article 6.3. http://library.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/tucsonazunifieddevelopmentcode?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

03. COMMENT: Provide a North arrow and scale bar to accompany site plan.

04. COMMENT: Include the square footage of the lot, existing dwellings, addition to dwelling, accessory structures, additions to accessory structures, and total under roof area, etc.

05. COMMENT: Provide the lot coverage calculation (the area of the site occupied be buildings, storage areas, vehicular use areas).

06. COMMENT: Show the location of square footage of the new structures and their use.

07. COMMENT: Indicate the new structure's maximum height.

08. COMMENT: Provide the height of the exterior walls of the building addition or structure, measured from the average height to the highest point under the roof.

09. COMMENT: Show the new structure's street perimeter setback, and the perimeter setback to the west.

10. COMMENT: Indicate the zoning of the property and the adjacent properties' zones.

11. COMMENT: Provide a legal description of the property (i.e. the subdivision name and lot number)

If you have any questions about this transmittal, Contact Loran Shamis by email Loran.Shamis@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
03/03/2020 JVWINKL1 LANDFILL REVIEW Passed
03/03/2020 JOHN VAN WINKLE ENGINEERING REVIEW Passed
03/03/2020 JVWINKL1 NPPO REVIEW Passed
03/03/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PROVIDE A COMPLETE SET OF CONSTRUCTION PLANS SHOWING COMPLIANCE WITH THE 2018 IRC.