Permit Number: T20CM00701
Parcel: 107091090

Address:
2640 N 15TH AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM00701
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change UPDATE SHEET A101 WITH NOTATION SHOWING THE METHOD OF APPLYING 1-HOUR FIRE RATED MATERIAL TO THE ROOF UNDERSIDE ALONG THE PROPERTY LINE OR REMOVE THE OVERHANG for compliance with R302.1
09/29/2020 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Steve Shields
Site Section Manager

PROJECT: T20CM00701
2640 N 15TH AV
CARPORT ADDITION

TRANSMITTAL: Date: September 29, 2020

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing a 2-foot setback to the north property line. With a wall height of 8'6" to natural grade, a 6-foot setback is required.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4).

The applicant is proposing a front facing attached carport with a wall height of 11'1" to natural grade facing the street perimeter (west) lot line. An 8' setback is proposed to the west lot line and a 20' setback is required.

DDO must be submitted and approved prior to approval of these building plans. DDO requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf
The DDO will need to be submitted at: https://www.tucsonaz.gov/file-upload-pdsd

Final Status

Task End Date Reviewer's Name Type of Review Description
10/17/2020 VFLORES1 APPROVAL SHELF Completed
10/17/2020 VFLORES1 OUT TO CUSTOMER Completed
10/17/2020 VFLORES1 REJECT SHELF Completed