Permit Number: T20CM00670
Parcel: 13609002D

Address:
10910 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM00670
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2020 MARTIN BROWN FIRE REVIEW Approved
04/30/2020 ANDREW CONNOR NPPO REVIEW Reqs Change Using the Set Aside Method requires the set aside area be done in a surveyable manner as a conservation easement, and recorded with the Pima County Recorder office.

Supply recordation documents and indicate recorded information on plans.
05/06/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM00670
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL COMMENTS:

1. Remove the clouded notation from sheet M1.1. Place review comments on a separate response correspondence located on a separate file.
2. Separate support documents such as structural calculations and mechanical sizing reports from construction plans. Place each document set in a separate PDF file.

MECHANICAL PLANS:

3. Provide whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the fresh air system and notation of the flow rate on sheet M1.1. Follow the guidance at page 486 and page 512 of the 2018 IRC.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
05/14/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. As previously commented, provide documentation of the City of Tucson approved subdivision. Include the activity number of the subdivision on the plan sheet.
05/18/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM00670
New Single Family Residence - Karen and Walt Patton (1st Review)
10900 E 22nd St.

TRANSMITTAL DATE: May 18, 2020

DUE DATE: May 21, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The new SFR plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

Previous comment 1. Provide City tracking number and approved documentation for the required subdivision. It appears that some type of subdivision is proposed. As the original parcel has been split at least twice for a total of 3 parcels a minor subdivision will be required. This subdivision will need to be approved prior to approval of the building plans.

Previous comment 4. This comment was not addressed correctly. The rezoning for the parcels to the south and east has not been effectuated the zoning should be listed as SR. Provide the zoning for the surrounding parcels on the site plan.

Previous comment 5. This comment was not fully addressed, provide the rezoning conditions on the plan. Provide the rezoning case number, C9-19-08, adjacent to the title block near the lower right corner of the plan. Also provide general note on the site plan that states the rezoning case number, dated of approval, and list all conditions of the rezoning.

Previous comment 6. This comment was not addressed some type of easement of agreement will need to be recorded for access to the southern parcel. Based on the site plan and the most current aerial photos there appears to be access being provided across this proposed parcel. If this access is to remain some type of access easement or access agreement is required. Once the easement or agreement is recorded provide the recordation information on the site plan.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans.