The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T20CM00670
Parcel: 13609002D

Address:
10910 E 22ND ST

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T20CM00670
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM00670
10900 E 22nd Street
New SFR
Residential (1st Review)

TRANSMITTAL DATE: January 30, 2020

The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

1. It appears that some type of subdivision is proposed. As the original parcel has been split at least 2 for a total of 3 parcels a minor subdivision will be required. This subdivision will need to be approved prior to approval of the building plans.

2. Remove the aerial photo from sheet AS1.

3. The zoning listed on sheet the cover sheet and sheet AS1 is not correct and should be listed as "EXISTING ZONING SR, PROPOSED ZOING RX-1".

4. Provide the zoning for the surrounding parcels on the site plan.

5. Provide the rezoning case number, C9-19-08, adjacent to the title block near the lower right corner of the plan. Also provide general note on the site plan that states the rezoning case number, dated of approval, and list all conditions of the rezoning.

6. Based on the site plan and the most current aerial photos there appears to be access being provided across this proposed parcel. If this access is to remain some type of access easement or access agreement is required. Once the easement or agreement is recorded provide the recordation information on the site plan.

7. As 22nd Street is an arterial street designated on the City of Tucson's Major Streets and Routes plan with a future right-of-way (ROW) width of 150' you must show the future ROW line and future curb on the plan and then demonstrate that the required street perimeter yard setback is met base on the future curb location, See Unified Development Code (UDC) Article 6.4.5.C.2. provided a dimension from center line of 22nd Street to the existing property line and a dimension from the center line of 22nd Street to the future curb and then to the future ROW line. Then provide a street perimeter yard setback from the back of future curb to the proposed house.

8. Remove the setback lines from the plan.

9. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
01/30/2020 SSHIELD1 NPPO REVIEW Needs Review
01/30/2020 SSHIELD1 ENGINEERING REVIEW Needs Review
01/31/2020 AMARTIN1 WWM REVIEW Passed
01/31/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review