Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM00560
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2020 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | FROM: Loran Shamis Planner PROJECT: T20CM00560 4938 E ROSEWOOD ST SFR addition TRANSMITTAL: March 13, 2020 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Applicant is proposing an addition to an existing SFR. The proposed wall height on the west side is 12'3". The proposed setback is 7' and the required setback is 8.2'. DDO required. |
| 03/19/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM00560 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. FLOOR PLANS: 1. Show compliance with R310 providing egress from bedrooms with a minimum net clear opening dimension of 20" width. Typically show either 4030XO or 3046SH or larger. Update the window size in bedroom #4. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. Provide plans for review. MECHANICAL PLANS: 1. Provide plans for review. ELECTRICAL PLANS: 1. Provide plans for review. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 03/19/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 04/21/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | FUP REQUIRED. SEE T20OT00326 The floor elevations for the existing rooms is not clear on the plans. Also, the FFE for the new construction is shown at two different numbers on the separate sheets. Make sure this is clarified on the next submittal. |