Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T20CM00543
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/24/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM00543 2723 E Linden St. Maher Residence Addition Residential (1st Review) TRANSMITTAL DATE: January 24, 2020 The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. The site plan shall be drawn at an Engineering scale, i.e. 1" = 20', 2. The provided lot coverage calculation does not appear to include the vehicle use area. 3. Provide the maximum structure height on the plot plan. 4. Provide the zoning for the surrounding parcels on the site plan. 5. Based on the most current aerial photos there appears to be several accessory structures located near the northwest corner of the parcel. If these structures are still on site they need to be shown on the plan and included in the lot coverage. 6. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 01/24/2020 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 01/24/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 01/27/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM00543 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. SITE PLAN: 1. Indicate the location of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1. STRUCTURAL PLANS: 1. Provide a header schedule and show opening sizes supporting new roof consistent with Table 502.5(1) & R602.7(1). 2. Provide a ridge beam sized with appropriate load carrying capacity, R802.3. Update keynote #2. 3. Provide a porch beam sized with appropriate load carrying capacity, R802.3. Update keynote #5. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update keynote #2, sheet A4.0. MECHANICAL PLANS: 1. Show dryer vent size and location for venting to exterior, M1501. ELECTRICAL PLANS: 1. Show the current code reference (2018 IRC) on the plans. 2. Clarify the electrical riser diagram, E3403. Notation shows 50A, the panel description shows 200A and the breaker protection shows 100A for the sub panel. 3. Protection of all interior new and extended 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. Update note #23 which only protects bedrooms. 4. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |