Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T20CM00527
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/24/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM00527 7752 e Camino Bavispe Detached Shed Residential (1st Review) TRANSMITTAL DATE: January 24, 2020 The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.6. The minimum setback is twenty feet facing each interior property line (Table 6.3-1.A). 1. The proposed shed location does not meet the minimum required perimeter yard setback of 20'-0". Either an adjacent neighbor signoff provided on the plot plan or Design Development Option (DDO) must be applied for and approved prior to approve of the plan. For the neighbor signoff a note similar to the following must be provided on the site plan and the adjacent owner must sign and dated; "MY NAME IS _________________ AND I AM THE OWNER OF THE PROPERTY LOCATED AT ____________________________, I HAVE REVIEWED THE PLOT PLAN AND I HAVE NO OBJECTION TO THE STRUCTURE BEING LOCATED OR CONSTRUCTED __________ FEET FROM THE PROPERTY LINE AS DEPICTED ON THE PLOT PLAN. SIGNATURE:____________________ DATE: _________________________ Or the DDO process must be completed. The DDO application package can be found at https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf 2. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 01/24/2020 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 01/24/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 01/24/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | 1. Each detached structure OVER 200SF requires a 3-foot fire separation distance from the property line and adjacent buildings, R302.1. 2. Roof projections may not extend to a point closer than 2 feet from the property line. Provide notation for compliance with R302.1 (City of Tucson Amended) by removing the roof overhang near the property line. R301.1. K E Van Karsen 520 837-4912 |
| 01/27/2020 | SBORZAK1 | WWM | REVIEW | Completed |