Permit Number: T19RW03330
Parcel: 999999999

Review Status: Completed

Review Details: ROW SWF - SUBMITTAL

Permit Number - T19RW03330
Review Name: ROW SWF - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2019 LINZUNZA START START Completed
06/25/2019 ROBERT SHERRY WATER REVIEW Passed
06/25/2019 LINZUNZA HISTORIC Review Approved RECOMMENDATION: Approval
06/25/2019 LINZUNZA IT_NETWK REVIEW Approved
06/27/2019 PROSENB1 DOT STREET MAINTENANCE REVIEW Approved Streets irrigation does not have any comments or concerns at this location at this time. Paul Rosenboom
07/01/2019 JSANDER1 DOT_ELEC REVIEW Approved
07/01/2019 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change Reviewer:

Richard Leigh
520-837-6647
richard.leigh@tucsonaz.gov


Traffic Conrol Plan:

Revise traffic control plan not overlaid on aerial photo. Drawing shall include the following:

* A plan view of the area to be barricaded. The plan should be situated so that North is up.

* Must have a north arrow

* All streets must be labeled.

* All side streets and alleys must be shown and labeled by name and if an alley as alley.

* All driveways must be shown.

* Dimension current lane widths.

* Show all bus stops.

* Clearly show pedestrian routing through or around worksite per MUTCD Chapter 6D.

* Label advanced warning area by dimensions and appropriate signing per MUTCD.

* Show all arrow boards and message boards and locate them per MUTCD.

* Show the transition area and dimension according to MUTCD.

* Show all lane tapers in transition areas according to MUTCD.

* Dimension between last barricade and turn areas reserved for driveway access or intersections

If bike lane will be close, provide "Share the Road With Care" per Additions By The City of Tucson To The MUTD for temporary Traffic Control, which can be found at https://www.tucsonaz.gov/files/transportation/files/2015_COT_Additions_Final.pdf
07/12/2019 JSANDER1 REAL_ESTATE REVIEW Needs Review
07/12/2019 JSANDER1 DOT_ELEC REVIEW Completed 3.95/3.92 AMPs