Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/06/2019 | JSANDER1 | START | START | Completed | |
03/06/2019 | JSANDER1 | HISTORIC | Review | Approved | Approved per Allison Diehl. |
03/14/2019 | RLEIGH1 | WATER | REVIEW | Approved | |
03/14/2019 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | 1. Locate AT&T meter outside of the sight visibility triangle. Please refer to City of Tucson Technical Standards Manual (COT TSM), Section 10-01.5.0 for sight distance requirements. 2. Depict and label the sight triangle per COT TSM Sec. 10-01.5.0 on plan view. COT TSM can be found at: http://library.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/technicalstandardsmanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az Please contact me at richard.leigh@tucsonaz.gov or 520-837-6647 if you have any questions. Richard Leigh Sr. Engineering Associate Tucson Dept of Transportation 520-837-6647 |
03/15/2019 | PROSENB1 | DOT STREET MAINTENANCE | REVIEW | Approved | Street Maintenance irrigation does not have any conflicts at this location on the west shoulder. |
03/19/2019 | LINZUNZA | IT_NETWK | REVIEW | Approved | |
03/20/2019 | JSANDER1 | REAL_ESTATE | REVIEW | Needs Review | |
03/27/2019 | JSANDER1 | DOT_ELEC | REVIEW | Denied | This pole will not work. Sheet A-3: The existing Type-1 streetlight poles that have the luminaire mounted at 40 FT use a 35 FT tall vertical shaft. The arm rises up 5 FT to make the 40 FT height. Here they propose using a pole that has the streetlight arm mounted at 30 FT and an arm that rises up 10 FT to make the 40 FT height. The only arm available to them is an arm similar to the one used on the Grant Rd installation which resembles the arms we use on the Type 2 A poles, "bent poles" as some people call them. This will not be symmetrical to existing arms. Sheet S-1 the drawing 1 does not indicate the correct luminaire mounting of 40 FT. Sheet G-1 N.T.S. 5 (Grounding Details) remove neutral wire and replace with a #12 Black 240 Volt wire. Remove the wire nut and the fuse to indicate a continuous #12 run from the City J-Box (pull box). The HEB-AA fuses will be located in the pull box not in the hand hole. The drawing on G-1 N.T.S. 5 needs to look like the drawing provided via email to applicant. |