Plan Number: T19PRE0225
Parcel: Unknown

Address:
443 W PLATA ST

Review Status: Completed

Review Details: PRESUBMITTAL MTG

Plan Number - T19PRE0225
Review Name: PRESUBMITTAL MTG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
12/11/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed 5.4.2. APPLICABILITY

The MS&R standards apply to the following uses on property, any portion of which abuts or is adjacent to a street designated on the City's or County's MS&R Plan:
A. New structures;
B. Changes of use, including new structures occurring on vacant land;
C. Uses of land or structures legally existing as of June 27, 1988, that are expanded in floor area, lot coverage, parking, seating capacity, or any other expansion of use, as listed below. Exception. An expansion of off-street parking for a nonconforming existing use that increases the number of spaces to the minimum required by the UDC for that use is exempt from counting toward the 25% expansion: (See Figure 5.4-A.)
1. If the expansion is less than 25%, the MS&R applies to the proposed expansion. The remainder of the use or structure shall be governed by provisions in force at the time of initial approval for the use or structure;
2. If the expansion is 25% or more, the MS&R applies to the proposed expansion and to the parking and landscaping standards that apply to the overall development; or,
3. Expansions that occur after the effective date of the MS&R shall be cumulated in determining the 25% expansion.
Provide expansion calculations.

If applicable show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
12/16/2019 GDAURIA1 COT NON-DSD FIRE Completed
12/16/2019 LOREN MAKUS ENGINEERING REVIEW Completed T1PRE0225 - 443 W Plata St
1. No floodplain
2. Not balanced or critical
3. Show solid waste container service location.
4. Show solid waste container storage location.
5. Existing parking along Plata and Oracle is not according to current standards.
12/17/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change Parking along Oracle and along W Plata not acceptable.

Close existing driveway on Oracle.

Sidewalk/walkable area required along W Plata (From oracle to proposed new sidewalk.
12/19/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting - T19PRE0225
Address: 443 W Plata St
Parcel(s): 115-15-0400
Zoning: C-2
Existing Use: Commercial Storage, Office, Residential
Proposed Use: Commercial Storage

TRANSMITTAL DATE: December 19, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is to demolish existing buildings on site and build a new 5,265 sq ft commercial storage building. The use is permitted in the C-2 zone, subject to use-specific standards 4.9.10.A.
3. Additional information is needed to determine the amount of expansion proposed. Provide the last approved site plan with submittal to determine. A cumulative expansion of 25% or more will require full code compliance for the site. If full code compliance is required, the parking along Oracle and Plata frontages must be removed and cannot be counted towards required parking. Additional sidewalks, landscaping and other site improvements may also be required.
4. Clarify existing and proposed uses on the site. From the street view it appears a theater company is housed in part of the building. Clarify whether this includes performance space or only office space.
5. The new building must includes sidewalks from each street and sidewalk between any parking area or access lane. It appears this standard is met.
6. Setbacks for the new building off of Plata and 13th are 21 ft or the height of the wall, as measured from outside edge of adjacent travel lane. Setback standards appear to be met.
7. Please note, this site is located within the Infill Incentive District (Greater IID) and may be eligible for modifications or reductions in development standards.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.