Plan Number: T19PRE0210
Parcel: Unknown

Review Status: Completed

Review Details: PRESUBMITTAL MEETING

Plan Number - T19PRE0210
Review Name: PRESUBMITTAL MEETING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/12/2019 LOREN MAKUS ENGINEERING REVIEW Completed 1. Not within flood hazard area.
2. Retention and detention are not required.
11/12/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
11/18/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply. New sidewalk along frontage is required.
11/20/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting - T19PRE0210
Address: 1016, 1026, 1036 S Fremont Av
Parcel(s): 124-17-087A, 124-17-086A, 124-17-085A
Zoning: R-2
Existing Use: Vacant
Proposed Use: Single-family residential

TRANSMITTAL DATE: November 20, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-07 Final Plat, Block Plat, Minor Subdivision, And Condominium Plat Applications.
2. The request is to re-subdivide 3 (or 4?) existing parcels into a total of 6 new single-family residential parcels.
3. Clarification is needed regarding which parcels and addresses are associated with this request. The parcel numbers and addresses do not match. I believe the request is for parcels 124-17-087A, 086A, 086B and 085A, which are associated with addresses 1016, 1026, 1028 and 1030 S Fremont Av.
4. In their current configuration, the lots in question would not meet minimum lot size for a total of 6 lots. If the right-of-way acquisition proceeds, it appears a total of approximately 30,150 sq ft is available to subdivide into 6 lots.
5. It is unclear whether the proposed configuration of homes would meet required setbacks. No dimensions were provided. Wall height is also needed. To Fremont St, the setback is 21 ft or the height of the wall, as measured from outside edge of adjacent travel lane. To the north and south property lines on each lot, the setback is 6 ft or 2/3 the wall height. Setbacks to the west are 10 ft or 3/4 the wall height.
6. Easements will need to be recorded for shared driveway access.
7. Verify proposed dimensions of the "flag" portion of each lot meet requirements for Tucson Water and other utility providers. Tucson Water has been requiring 15 ft minimum frontage for each lot.
8. It appears this application is eligible for submission of a Minor Subdivision application, pending resolution of the items mentioned here.
9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Minor Subdivision review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
11/20/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 210 pm - T19PRE0210 - 1036 S FREMONT AV - TENTATIVE PLAT Miramonte Fremont
" Each of the six proposed lots must have at least 15' of frontage on Fremont Avenue, and the site plans shows that three of the lots will only have 12' of such frontage.
" The draft site plan does not show the necessary underground electrical utilities, but please be aware that that water service lines may not be located within 10' of any electrical pedestals and within 5' of any other utility line.
11/22/2019 MASHFOR1 COT NON-DSD FIRE Completed Fire Hydrants and square footage of the structures will need to be identified on the plan set moving forward