Plan Number: T19PRE0204
Parcel: Unknown

Address:
1222 S FREEWAY

Review Status: Completed

Review Details: PRESUBMITTAL MEETING

Plan Number - T19PRE0204
Review Name: PRESUBMITTAL MEETING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed 7.6. LANDSCAPING AND SCREENING

7.6.2. APPLICABILITY
The provisions of this section apply to the following:

A. All new development; and,
B. Expansion of existing development, as provided below:

1. Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:

a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.

b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.

Provide expansion calculation.
11/12/2019 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is within 500-year floodplain. No special consideration for this project.
2. Maximize water harvesting in landscape areas.
11/18/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply.
11/20/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 pm - T19PRE0204 - 1222 S FREEWAY - SITE IID Regal Inn
" An existing 8" ductile iron water main runs north-south along the east side of this property in a 15' wide utility easement not clearly labeled on the site plan, and the proposed wrought iron fence and large tree may be within this easement.
" None of the proposed improvementsor plantings may encroach into this 15' utility easement and cause it to become undrivable.
" Note that Section 4.3 of Tucson Water Design Staandard 8.08 requires special precautions to be taken when planting trees near existing water lines to prevent root intrusion.
11/21/2019 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers; Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0204
Address: 1222 S Freeway Road
Parcel(s): 11808009B, 11808008B, & 11808015A
Zoning: C-2
Existing Use: Travelers' Accommodation
Proposed Use: Travelers' Accommodation

TRANSMITTAL DATE: 11/21/2019

COMMENTS:
01. Development must comply with the Administrative Manual Section 2-06 - Development Package.
02. The proposal is for an expansion of an existing hotel in the C-2 zone. Travelers' Accommodation is a permitted use with no use specific standards. Food Service and Alcoholic Beverage Service: Excluding a Large Bar are permitted accessory uses. Alcoholic Beverage Service: Excluding a Large Bar is subject to use specific standards 4.9.13.P.

03. The development is shown on three separate parcels, a lot combination will be required.

04. If expansion is more than 25% full code compliance on the entire site will be required. Provide additional info to determine the % of expansion.

05. Parking for a travelers' accommodation is required at 1 space per rental unit plus 1 space per 300 sq. ft. GFA of conference, restaurant, retail, bar, and banquet space. For a 3200 sqft expansion 11 spaces will be required. Not enough has been information provided to determine if the site will be meeting parking requirements with the expansion.

06. Pedestrian access is required on all sides of the new building and to the street.

07. Starr Pass Blvd is an MS&R; MS&R setbacks will apply to all street side setbacks. The west setback will be 21' from nearest edge of travel. The North and west setbacks will be 21' from the back of existing or future curb location.

08. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.



If you have any questions please contact me at samuel.rogers@tucsonaz.gov or (520) 837-6932.
11/26/2019 SBEASLE1 COT NON-DSD FIRE Passed