Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION
Plan Number - T19PRE0197
Review Name: PREAPPLICATION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 10/25/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | The site has an area of 0.42 acres. The site is neither balanced nor critical: retention and detention are not required. The development must make maximum use of water harvesting for landscape purposes. Centralized collection of solid waste is required. Provide waste stream calculation. |
| 10/29/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | Standard requirements will appply |
| 10/29/2019 | MASHFOR1 | COT NON-DSD | FIRE | Completed | Fire Sprinklers may be required for R usage for these Lofts. Smoke detectors related to Fire Alarms will be required. Please discuss with Glenn D Auria at the Pre-submittal meeting to further assist you. |
| 10/30/2019 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting - T19PRE0197 Address: 3415 E 1st St Parcel(s): 125-12-0450 and 0460 Zoning: R-3 Existing Use: Vacant Proposed Use: Multifamily development TRANSMITTAL DATE: October 30, 2019 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for seven residential units on an approximately 17,000 square foot site. Density standards and most development standards appear to be met with this proposal. 3. The proposed interior perimeter yard setback does not meet standards. The required setback is 10 ft of ¾ of the wall height. Based on a height of 19 ft 8 in, a 14 ft 9 in setback is required to the north, east and west. A Design Development Option is an administrative review process which may reduce the required setbacks and may be an option for this development. 4. Parking standards appear to be met, however additional information is needed on parking space, access aisle and back-up spur dimensions. Please note the provided accessible parking space must also be van accessible. 5. Short-term bike parking must be provided at a ratio of 0.1 spaces per bedroom. Long-term bike parking must be provided at a ratio of 0.5 spaces per bedroom. A total of 2 short-term and 11 long-term bike parking spaces must be provided. Long-term bike parking may be provided within individual residential units. 6. A sidewalk is required from the street to the residential buildings. 7. As development is proposed over two parcels, a lot combination will be required to be processed with Pima County. Documentation will be required as part of development package review. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
| 10/31/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 pm - T19PRE0197 - 3415 E 1ST ST - SITE Torrez Lofts 1. Tucson Water has an 8" cast iron water main that runs east-west inside the north side of this property in the 5' utility easement south of the 20' alley. This 8"cast iron water main also runs north-south inside this property along the upper half of the west side of this property in another utility easement. No permanent structures of any kind (walls, bulidlings, roofs, etc.) may intrude into these utility easements. 2. The drawing submitted with this application is unclear in many respects, but appears to show masonry walls being constructed into these easements for the purpose of providing a private backyard for each unit. If that is the case, these walls may not intrude into these easements. 3. There is a 4" water main in First Street which can supply water to the proposed development. Tim Rowe, Sr. Engineeering Associate Tucson Water 310 W. Alameda St. Tucson, AZ 85701 (520) 837-2106 |