Plan Number: T19PRE0176
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0176
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
09/27/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0176
Address: 9290 E Golf Links Rd
Parcel(s): 136-33-148C
Zoning: O-3
Existing Use: Vacant
Proposed Use: Multi-family residential

TRANSMITTAL DATE: September 27, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a new 80-unit multi-family residential complex. This is a permitted use in the O-3 zone. The concept appears to generally meet development standards and conform with zoning regulations.
3. Building height is listed incorrectly. Max building height is 40 ft.
4. The proposed density is not calculated correctly. Max density in the O-3 is 22 units per acre. This proposal appears to be roughly 20 units per acre.
5. A total of 152 parking spaces are required. One-bedroom units each require 1.5 parking space. Two-bedroom units each require 2 parking spaces.
6. Bike parking is required. Short-term bike parking Is 0.1 spaces per bedroom. Long-term bike parking is 0.5 spaces per bedroom.
7. Setbacks on the south, east and west are 10 ft of ¾ the wall height. Setback off Golf Links is 21' or the wall height as measured from the back of future curb.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
09/27/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed No Comments.

Tim Rowe, Sr. Engineeering Associate
Tucson Water, 310 W. Alameda St.Tucson, AZ 85701
(520) 837-2106
10/01/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed FROM: Zelin canchola Transportation

PROJECT: Thursday Pre-submittal meeting T19PRE0176
Address: 9290 E Golf Links Rd

Standard requirements will apply during the development plan proccess.
10/01/2019 MASHFOR1 COT NON-DSD FIRE Completed Please provide the proper Fire Sprinkler/Alarm notes on the plan set as this project progresses. Also identify all current and or proposed fire hydrants (water Source). Identification of fire access and locations.

***Fire Sprinklers will be required on this project
Occupancy type/usage should also be provided on the plan set.
10/09/2019 SBEASLE1 ENGINEERING REVIEW Completed