Plan Number: T19PRE0167
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0167
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/12/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
09/12/2019 MASHFOR1 COT NON-DSD FIRE Completed As plans are submitted please provide all Fire Department Access, and current/future fire hydrants to identify (water sources) and or locations.
09/17/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed A (TIA) Traffic Impact Analysis will be required.
09/23/2019 LOREN MAKUS ENGINEERING REVIEW Completed TT19PRE0167
1. Retention and detention must meet the requirements of the PAD section starting on page 99 of the PAD document.
2. Confirm that Multifamily Development is allowed in the western portion of this site.
3. Demonstrate the road crossing of the wash natural open space is necessary.
09/25/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0167
Address: 10220 E Drexel Rd
Parcel(s): 141020190, 0200
Zoning: PAD-30
Existing Use: Vacant
Proposed Use: Residential - Multi-family residential

TRANSMITTAL DATE: September 25, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for 15 multi-family residential buildings within the Saguaro Trails PAD (PAD-30). The site is divided by a wash, with approximately half the site in Planning Area "B" and half in Planning Area "C".
3. Per the PAD, multi-family residential is not permitted in Planning Area C. Exhibit III.1 and Section III.B.1.C both describe this area as Single-Family Attached/Single-Family Detached.
4. Per PAD Section II.B.2.D. multi-family residential is limited to 36 units per acre. Parking is required based on the types of units. Additional information on total and types of units is needed to determine compliance.
5. Other development standards for multi-family residential per the PAD appear to be met with this proposal.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
09/30/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed T19PRE0167 - 10220 E DREXEL RD - SITE Encantada at Saguaro Trails, multi-family

1. There is an existing 12" PVC water main on the south side of this project, and a new 12" water main is being constructed on the north side of this project. Both are dead-end water lines. The on-site water mains will need to connect to both of these dead end lines near the west end of the development and form a loop.
2. The water pressure in this area is in the 42 to 53 psi range.

Tim Rowe
Tucson Water
Tim.Rowe@TucsonAz.gov