Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION
Plan Number - T19PRE0148
Review Name: PREAPPLICATION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 08/16/2019 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | Please identify all the fire hydarnts (water source) on the plan set. Also, please make sure there is proper fire access available to adress all structures in the area. |
| 08/16/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. 500-year floodplain. Critical facilities must meet standards, if applicable. 2. Centralized collection required for solid waste. 3. Align driveway to 21st Street with Ochoa Lane. |
| 08/19/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. |
| 08/20/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 215 pm - T19PRE0148 - 910 W STARR PASS BL - SITEGRADING - Eight new SFRs - Where will the proposed development connect to a new or existing water main? - Will the 8 single family residences be served by a master water meter, or individual meters? Note that a 10' x 25' easement is required for 3" or larger above ground meters, and 2" meters are the largest allowable underground meters. - What fire flow requirement has the Fire Department specified for this development? - The proposed public water line extension will need to go through Tucson Water's Master Plan process, and looping of the water line will almost certainly be required to meet fire flow and water quality requirements. Fabien A. Elenes, Engineering Associate P.O. Box 27210, Tucson, AZ 85726-7210 (520) 837-2202 Fabien.Elenes@TucsonAZ.gov |
| 08/21/2019 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting T19PRE0148 Address: 910 W Starr Pass Bl Parcel(s): 11623108A Zoning: R-2 Existing Use: Vacant Proposed Use: Multi-Family Residential TRANSMITTAL DATE: August 19, 2019 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for a multi-family residential development consisting of 8 free-standing rental units. The use is permitted in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, & .10. 3. Pedestrian access, lot coverage and setbacks as indicated on the proposal appear to be adequate. 4. Parking requirement may be less than indicated on the proposal, depending on the total number of bedrooms in each unit. 5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |