| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | PAD-29 Permitted Uses Permitted uses for the entire Property shall include all uses that are listed as permitted or as special exception uses in the C-2 zone of the City Unified Development Code ("UDC"), except as modified in this PAD. Multifamily is permitted use C-2 zone Verify graphically, where possible, compliance with PAD-29 document. Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 08/07/2019 | MASHFOR1 | COT NON-DSD | FIRE | Completed | Fire Sprinklers will required on this project per IFC 2018 Section, 903.2.8 All R occupancies require Fire Sprinklers. Please add the Fire Sprinkler note to the plan set moving forward. Fire Alarm/Smoke detection. Please refeer to Section 907 of the 2018 IFC. for R occupancies (R-2). Notate on the future plan set. Provide all fire hydrant locations and fire access to the future plan set |
| 08/09/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Waste stream calculations are not correct. Both the City Code provisions and the waste stream calculations from the technical standards must be met. |
| 08/12/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. |
| 08/15/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | This will require a revised Overall Master Plan, a new Phased Master Plan and a new Design Plan for the layout. It will need to tap on the SE area and the NW area of the overall site into existing water lines. Thank you, Fabien A. Elenes, Engineering Associate P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 Fabien.Elenes@TucsonAZ.gov |
| 08/15/2019 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting T19PRE0146 Address: 4400 S Landing Wy Parcel(s): 137-05-5870, -5880 & 120-04-003H Zoning: PAD-29 Existing Use: Vacant Proposed Use: Residential - Multifamily TRANSMITTAL DATE: August 14, 2019 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for 127 units of multi-family housing. This is a permitted use per PAD-29. 3. As the proposal is for a unified development across multiple lots, a lot combination will need to processed with Pima County prior to development approvals. All lots will need to be combined 4. Pedestrian access is required from Irvington Rd. Ensure this standard is met. 5. Per PAD section III.C. vehicular parking shall be provided at 1 space per 300 square feet for all permitted use. It appears this would require a higher than standard parking requirement for this use. A minor amendment or clarification letter may be warranted from the Rezoning staff. Please contact John Beall at john.beall@tucsonaz.gov or 837-6966. 6. If a shared parking agreement is in place for the entirety of the PAD area, documentation will be required at the time of development package submittal. 7. Per PAD section III.C.14. an Architectural Review Committee shall review all proposed architectural plans. Through a self-certification process, the ARC will provide a letter of approval to the City at time of development package submittal. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. 9. Follow-up comment from meeting: this may be processed as a revisions to the existing tentative plat/development package. A entirely new development package will not be required. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |