Plan Number: T19PRE0135
Parcel: Unknown

Address:
6455 S WILMOT RD

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0135
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
07/26/2019 MASHFOR1 COT NON-DSD FIRE Completed
07/29/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed July 29, 2019
Address - 6455 S Wilmot Rd
Project name - Convert existing use to RV Storage Facility
Reviewer - Zelin Canchola

Modification to the existing roadway striping will be required to accomodate left turns onto proposed project. A PIA will be required.
07/30/2019 LOREN MAKUS ENGINEERING REVIEW Completed 1. Since the drive aisles are paved, the storage locations can be crushed rock or gravel. No minimum size is specified.
8. Vehicle use areas must be paved. Vehicle Storage areas may be crushed rock or gravel.
9. Mitigation of the previous disturbance of the riparian resources in the floodplain may be required.
07/31/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0135
Address: 6455 S Wilmot Rd
Parcel(s): 141-03-025E
Zoning: I-2
Existing Use: Vacant
Proposed Use: Storage - Personal Storage

TRANSMITTAL DATE: July 31, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a personal storage facility for recreational vehicles. This is a permitted use in the I-2 zone, subject to use-specific standards 4.9.10.C.3 & .6 and 4.9.13.Q. Please note, these sections note standards regarding building materials for a personal storage use.
3. Wilmot Rd is designated as a Major Street & Route. Setbacks will be 21' or the height of the structure, as measured from the back of future curb. Littletown Rd will have the same setback.
4. This site is located within the Davis-Monthan Air Force Base Airport Overlay. This includes Noise Control Zone B, Approach-Departure Corridor 2 and Land Use Overlay Zone 3. The proposal appears to meet the standards of this overlay.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
08/01/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed There is an existing one inch water service that is available to this site. Please see Ray Munoz in New Services for water meter information. If fire flow requirements need additional infrastructure for compliance purposes please let Tucson Water New Development or New Services know what the location of any required fire hydrants and duration of fire flow need to be.

Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water
310 W Alameda St.
Tucson, AZ 85701
520-837-2048
08/05/2019 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Completed