Plan Number: T19PRE0121
Parcel: Unknown

Address:
3940 E 29TH ST

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0121
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Landscape has no comments unless expansion of 25% or greater is proposed.
07/10/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed There is an existing water service that serves this site. There is a fire hydrant across the street. If additional fire suppression is needed for this site there is a 12" Tucson Water line on the north side of East 29th street that can be tied into. If the applicant would prefer not to connect to this line due to pavement replacement cost but still needs additional fire suppression then there are 6" and 4" diameter Tucson Water lines stubbed out on the south side of the Citation Wash bordering the south side of this parcel. These can be tied into if desired to avoid cutting into the pavement in East 29th Street.
Please let me know if you have any comments, questions or concerns.
Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water, 310 W Alameda St., Tucson, AZ 85701
520-837-2048
07/10/2019 JOHN VAN WINKLE ENGINEERING REVIEW Completed T19PRE0121

1) Project site and building is impacted by the Citation Wash Floodplain. Any building renovations or additions would be subject to chapter 26 of the Tucson City Code regarding substantial improvements. Building improvements/expansions would be limited to 50% of the value of the existing building without triggering floodplain compliance for the entire structure
2) a floodplain use permit will be needed
07/11/2019 MASHFOR1 COT NON-DSD FIRE Completed
07/16/2019 STEVE SHIELDS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Steve Shields, Section Manager

PROJECT: Addition to Bar
Address: 3940 E 29th Street
Parcel(s): 130-18-001B
Zoning: C-2
Existing Use: Alcoholic Beverage Service
Proposed Use: Alcoholic Beverage Service - Subject to Use Specific Standard 4.9.13.P.

TRANSMITTAL DATE: July 15, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Provide a copy of the last approved site plan with your plan submittal.
3. Based on a Zoning Administration letter dated February 4th, 2016 the existing structure gross floor area was 2,013 SF. Based on this information the proposed 525 SF expansion is a greater than 25% expansion and per UDC Article 7.4.3.E.2 the entire site must meet the requirements of UDC Article 7.4.
4. Per TSM 7-01.4.1.A a sidewalk is required from the proposed expansion out to the sidewalk along 29th.
5. Per TSM 7-01.4.1.C a 4' wide sidewalk is required along the north side of the proposed expansion and along the south side of the building.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at steve.shields@tucsonaz.gov or (520) 837-4966.
07/16/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed July 16, 2019
ACTIVITY NUMBER: T19PRE0121
PROJECT NAME: Neighborhood Bar
PROJECT ADDRESS: 3940 E 29th Street
PROJECT REVIEWER: Zelin Canchola TDOT

Resubmittal Required: The following item are based on Full Code Compliance.

1. Show improvements within right of way according to PAG Standard details, and elevations.

2. A right of way permit will be required for work within the right of way.

3. Close west Driveway. A safety hazard exists with vehicle backing on to right of way.

4. Replace east driveway with new PAG standard driveway. Existing does not meet ADA standards.

5. Close any unused driveways.


If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
07/23/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed