| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/09/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 07/10/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | The site has an existing water service and an existing fire hydrant adjacent to the site. If there are any additional water needs, these can likely be coordinated directly with Ray Munoz in Tucson Water New Services Section. He can be reached at 520-837-2207. Thanks. Paul Baughman, PE, CFM Civil Engineer Tucson Water, 310 W Alameda St. Tucson, AZ 85701 520-837-2048 |
| 07/10/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Completed | T19PRE0120 1) Project site and building is impacted by the Nebraska Wash Floodplain. Any building renovations or additions would be subject to chapter 26 of the Tucson City Code regarding substantial improvements. Building improvements/expansions would be limited to 50% of the value of the existing building without triggering floodplain compliance for the entire structure 2) a floodplain use permit will be needed John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 07/11/2019 | MASHFOR1 | COT NON-DSD | FIRE | Completed | Please make sure the occupancy usage/type/load are listed moving forward. Please also list if the current structure posses Fire Sprinklers/Alarm/Hood. Put the fire hydrant (water source) locations on the plan set. Thank you |
| 07/15/2019 | STEVE SHIELDS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Steve Shields, Section Manager PROJECT: Change of use and expansion Address: 5256 S Nogales Hwy Parcel(s): 137-03-1130 & 137-03-1140 Zoning: C-2 Existing Use: Retail Proposed Use: Food Service - Subject to Use Specific Standards 4.9.4.M.1 and 4.9.13.P. TRANSMITTAL DATE: July 15, 2019 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. As this site is made up of two (2) parcels a lot combination is required. 3. Provide a copy of the last approved site plan with your plan submittal. 4. This site is located within the TIA Avigation Easement and Disclosure Area. 5. As no calculation; expansion, vehicle & bicycle parking etc. were provide comments are very limited. You will need to review UDC Articles 7.4.3.E, 7.6.2.B, 7.7.3.B and TSM Section 7-01.2.B for code compliance requirements based on expansions. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at steve.shields@tucsonaz.gov or (520) 837-4966. |
| 07/16/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | July 16, 2019 ACTIVITY NUMBER: T19PRE0120 PROJECT NAME: Miss Saigon PROJECT ADDRESS: 5256 S Nogales Hwy PROJECT REVIEWER: Zelin Canchola TDOT Resubmittal Required: The following item are based on Full Code Compliance. 1. Show improvements within right of way according to PAG Standard details, and elevations. 2. A right of way permit or private improvement agreement (PIA) will be required for work within the right of way. 3. Provide/Replace driveway according to PAG standard details along Nogales Hwy to meet ADA standards. 4. New pavement along Olive Street required along Olive Street frontage. Maintain existing drainage patterns. A PIA will be required for this work. 5. Provide a barrier along new parking area from Olive Street to prevent access onto parking area. If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov |
| 07/23/2019 | ALEXANDRA HINES | ZONING-DECISION LETTER | WRITE DECISION LETTER | Completed | Pre-Submittal Complete Notice: T19PRE0120 Project Description: SITE - Miss Saigon restaurant Prior to submitting, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above. Alexandra Hines, AICP | City of Tucson Planning and Development Services - Lead Planner | 201 N Stone Ave 1st Floor, Tucson, AZ 85701 | (520) 837-6975 - alexandra.hines@tucsonaz.gov |