Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T19PRE0117
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0117
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/02/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Note:

Structural Overhang

Covered parking canopies or other structural canopies, such as those used in service stations, may not overhang into street landscape borders in order to avoid conflicts between the structures and crowns of trees.
07/02/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed There are existing public City of Tucson Water lines and easements in the vicinity of the proposed northern Canopy. See Docket 5568 Page 938 and Docket 12154 Page 2988 for easement details. Please show these water lines and easements on site plan with proposed offsets between existing public waterlines and proposed structural elements.

There is also a public water line near the location of the southern canopy. The water line location should be shown in relation to this canopy to ensure a safe offset.
Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water, 310 W Alameda St., Tucson, AZ 85701
520-837-2048
07/05/2019 STEVE SHIELDS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Steve Shields, Section Manager

PROJECT: Thursday Pre-submittal meeting
Address: 3605 E Broadway Blvd
Parcel(s): 125-10-1380
Zoning: C-1/C-2
Existing Use: Food Service
Proposed Use: Food Service - Drive through canopies

TRANSMITTAL DATE: July 5, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Maximum height: 30' in C-1 zone and 40' in C-2 Zone
3. Perimeter yard requirements: Street - 21' or (H) measured to the back of existing curb. Interior lot line 0'. Interior access lane 1'-0". H = The height of the proposed exterior building wall. In all circumstances, the greater setback resulting from the alternate measurement is required.
4. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at steve.shields@tucsonaz.gov or (520) 837-4956.
07/08/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply.
07/08/2019 JOHN VAN WINKLE ENGINEERING REVIEW Completed Engineering has no comments at this time
07/11/2019 MASHFOR1 COT NON-DSD FIRE Completed
07/15/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Pre-Submittal Complete Notice: T19PRE0117
Project Description: SITE - CHICK-FIL-A CANOPY
Prior to submitting, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above.

Alexandra Hines, AICP | City of Tucson Planning and Development Services - Lead Planner | 201 N Stone Ave 1st Floor, Tucson, AZ 85701 | (520) 837-6975 - alexandra.hines@tucsonaz.gov