Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T19PRE0108
Parcel: Unknown

Address:
2720 E RIVER RD

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0108
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Obtain permission for cross access parking.
Any new parking will need to meet canopy tree requirement:
Canopy Trees in Vehicular Use Areas

General Standards

Within a vehicular use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof.
(1) The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk).
06/12/2019 GDAURIA1 COT NON-DSD FIRE Completed
06/14/2019 JOHN VAN WINKLE ENGINEERING REVIEW Completed T19PRE0108

1) Minimum width for a PAAL accessing 90 degree parking is 24'. Current proposal shows PAAL to only be 20' wide. UDC table 7.4.6-1
2) Vehicle overhang past curb or wheel stop should be 2.5'. 3' is shown
3) Water harvesting for the added impervious area will be required

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
06/17/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Standard improvements in the right of way will be required.
06/20/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed There is an existing 12" water line that provides fire and potable water service to this property. Please see Tucson Water's Distribution design section to determine impacts of proposed parking to our water line. There may be restrictions on the location of vegetative root balls to our existing water line.
Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water, 310 W Alameda St., Tucson, AZ 85701
520-837-2048
06/20/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0108
Address: 2720 E River Rd
Parcel(s): 108-24-008F and 108-24-006C
Zoning: O-3
Existing Use: Residential Care Services - Adult Care Service
Proposed Use: Same

TRANSMITTAL DATE: June 20, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is to add a new parking area straddling two properties, but serving the Haciendas at the River residential care service facility.
3. As the new parking area will straddle a property line not under common ownership, a parking and access agreement need to be recorded to run with the properties.
4. A new development package must be submitted which covers both sites as built and illustrates the proposed modifications.
5. Please note, a two-way parking area access lane is required at 24' in width. Also verify that the addition of parking spaces will not alter the required number of accessible parking spaces to be provided on site.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
06/28/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Pre-Submittal Complete Notice: T19PRE0108
Project Description: SITE/OCZ - HACIENDAS AT THE RIVER
Prior to submitting, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above.

Alexandra Hines, AICP | City of Tucson Planning and Development Services - Lead Planner | 201 N Stone Ave 1st Floor, Tucson, AZ 85701 | (520) 837-6975 - alexandra.hines@tucsonaz.gov