Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION
Plan Number - T19PRE0095
Review Name: PREAPPLICATION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T19PRE0095 1. Curb return for speedway entrance must be 25-foot radius. 2. "Shared alley is part of Adair Funeral Home property. Show easement recordation on plans. 3. Legal access to and from the solid waste collection location must be established on the DP. |
| 06/04/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | It is anticipated that any water service requirements may be able to be handled through our new Services Section at 201 N Stone. Thanks. Paul Baughman, PE, CFM Civil Engineer Tucson Water 310 W Alameda St. Tucson, AZ 85701 520-837-2048 |
| 06/04/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. SECTION 4-01.0.0: COMMERCIAL RAINWATER HARVESTING 1.3 Applicability This standard applies to all commercial development plans submitted after June 1, 2010. |
| 06/05/2019 | MASHFOR1 | COT NON-DSD | FIRE | Completed | |
| 06/11/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | |
| 06/12/2019 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting, T19PRE0095 Address: 3700 E Speedway Parcel(s): 125-10-023A, 125-10-0220, 125-10-020C Zoning: C-2 Existing Use: Commercial Proposed Use: Commercial: Food Service TRANSMITTAL DATE: June 12, 2019 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is the construction of new Food Service use. The use is permitted in the C-2 zone and is subject to use-specific standards 4.9.4.M.1 and 4.9.13.P. 3. The required setback on Speedway is 21' or the building height, as measured from back of future curb. On Dodge, the required setback is 21' or the building height, as measured from the outside edge of adjacent travel lane. To the east and south the required setback is 0'. 4. Parking is required at a ratio of 1 space per 100 sq. ft. of building and outdoor seating area. Additional information is needed to verify the requirement with this proposal. Bicycle parking is also required, with 2 short-term and 2 long-term spaces with this proposal. 5. At least one sidewalk is required to a project from each street on which the project has frontage. The sidewalk should be located to minimize any conflict with vehicular access to the project. As discussed in the pre-submittal meeting, pedestrian access is also required to the dumpster area, but my potentially be modified through a TSMR process. 6. The project site encompasses three parcels. A lot combination, processed through Pima County, is required prior to approval of a development package. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
| 06/18/2019 | ALEXANDRA HINES | ZONING-DECISION LETTER | WRITE DECISION LETTER | Completed | Pre-Submittal Complete Notice: T19PRE0095 Project Description: SITE - DUTCH BROS COFFEE Prior to submittal, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above. Alexandra Hines, AICP | City of Tucson Planning and Development Services - Lead Planner | 201 N Stone Ave 1st Floor, Tucson, AZ 85701 | (520) 837-6975 - alexandra.hines@tucsonaz.gov |