Address:
3727 N STONE AV

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0093
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2019 LOREN MAKUS ENGINEERING REVIEW Completed 1. No flood hazard areas.
2. Stone Avenue is at full width. (90 feet) R-83-006
3. Critical Basin. Detention required. This will likely be achievable with water harvesting.
4. Show solid waste service locations.
06/04/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed Please work with Ray Munoz at 837-2207 in the Tucson Water New Services section at 201 N Stone for water service requirements, including water meters, fire services and fire hydrants that may be needed to support this development.
Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water
310 W Alameda St.
Tucson, AZ 85701
520-837-2048
06/04/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
06/05/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Close any unused driveways at time of development.
06/05/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting T19PRE0093
Address: 3727 N Stone Av (3737 noted on application materials)
Parcel(s): 106-02-201A
Zoning: R-2
Existing Use: Vacant
Proposed Use: Multi-Family Residential

TRANSMITTAL DATE: June 5, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a cluster of duplexes on an approximately 26,500 sq ft lot.
3. This zone allows a density of 15 units per acre. This site would allow approximately 9 total units per density standards.
4. Parking requirements for this development depend on the bedroom count within in each unit. Two-bedroom units require 2 parking spaces each. Three-bedroom units require 2.25 parking spaces each.
5. Bicycle parking must also be provided. Short-term bike parking is required at 0.1 spaces per bedroom, minimum of 2 spaces. Long-term bike parking is required at 0.5 spaces per bedroom, minimum of 2 spaces. Accessible parking must also be provided at a ratio of 1 space per 25 standard spaces provided.
6. Setbacks for this property will be 10' or ¾ the wall height to the north, south, and west property lines. The street setback is required at 21' or the structure height, as measured from the back of the future curb location.
7. Pedestrian access (sidewalk) will be required from Stone Av to the entrance of each unit.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
06/05/2019 MASHFOR1 COT NON-DSD FIRE Completed
06/10/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Pre-Submittal Complete Notice: T19PRE0093
Project Description: SITE- 8 RESIDENTIAL UNITS
Prior to submitting, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above.

Alexandra Hines, AICP | City of Tucson Planning and Development Services - Lead Planner | 201 N Stone Ave 1st Floor, Tucson, AZ 85701 | (520) 837-6975 - alexandra.hines@tucsonaz.gov