Plan Number: T19PRE0039
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0039
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.

7.7. NATIVE PLANT PRESERVATION

7.7.3. APPLICABILITY
All new development proposed in the City of Tucson shall comply with the standards of this section.

4-01.0.0: COMMERCIAL RAINWATER HARVESTING

1.3 Applicability
This standard applies to all commercial development plans submitted after June 1, 2010.

A Rainwater Harvesting Plan shall be submitted with all applications for commercial developments at which landscaping is required.
03/07/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed March 13, 2019
ACTIVITY NUMBER: T19PRE0039
PROJECT NAME: New Animal Hospital
PROJECT ADDRESS: 9210 E Valencia
PROJECT REVIEWER: Zelin Canchola TDOT

TDOT offers the following comments:

1. Provide new 6 foot wide sidewalk along Valencia, along with new curb.

2. Repair and improve existing driveway to current standards if necessary.

3. New west bound left turn lane to existing driveway will be required.

4. A private improvement agreement will be required.


If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
03/07/2019 MASHFOR1 COT NON-DSD FIRE Completed Please make sure that all fire hydrants (water sources) are located on the plan set and fire access is identifiable. TFD will review once plans are submitted for any additional fire needs
03/11/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed The Proposed Valencia Animal Hospital is located south of a 16" diameter transmission main. Per Tucson Water Design Standard 8-08.3.2C1 There shall be no fire hydrant or service connection located directly on transmission mains over twelve-inches. Please see Tucson Water New Services if the water service requirements for this development can be met through a Job Order Contract. Alternatively, Tucson Water New Development will be happy to assist the applicant through our master planning and design review processes. Please contact me at Tucson Water new development if a job order contract will not work for this development and I will provide additional assistance.

Best Regards,
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water
310 W Alameda St., Tucson, AZ 85701
520-837-2048
03/12/2019 LOREN MAKUS ENGINEERING REVIEW Completed 1. Show how water harvesting will be maximized.
03/13/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting (T19PRE0039)
Address: 9210 E. Valencia Rd
Parcel(s): 141390010
Zoning: C-2
Existing Use: Vacant
Proposed Use: Commercial: Animal Service

TRANSMITTAL DATE: March 13, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a 5,000 sq ft animal hospital to be constructed off Valencia Rd. The draft site plan that was provided appears to generally conform with development standards of this zone and location. Clarification is needed regarding driveway improvements and shared access with the site to the west.
3. Animal service is a permitted use in the C-2 zone, subject to use-specific standards 4.9.4.D.1, .2, .3, & .4 and 4.9.13.P or 4.9.4.D.7 & 4.9.4.D.10-.15. These standards limit overnight confinement, boarding, outpatient for small animals. Activity must also be conducted within an enclosed building. Clarification is needed to determine if these standards will allow the use as proposed.
4. If the use does not meet the above standards, it is subject to use-specific standards 4.9.4.D.9 - .15 and requires a zoning examiner special exception procedure. These standards address setbacks, fencing, waste removal, outside exercise, operational hours and noise level. Clarification is needed to determine if these standards will allow the use as proposed.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
03/18/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Pre-Submittal Complete Notice: T19PRE0039
Project Description: SITE/GRADE - VALENCIA ANIMAL HOSPITAL
Prior to submitting, view the meeting review details on www.tucsonaz.gov/pro, search by activity number above.

Thank you,
Alexandra Hines, AICP
Lead Planner at Planning and Development Services, City of Tucson
201 N Stone Ave 1st Floor, Tucson, AZ 85701
(520) 837-6975 - alexandra.hines@tucsonaz.gov