Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T19PRE0016
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0016
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
SECTION 4-01.0.0: COMMERCIAL RAINWATER HARVESTING
1.3 Applicability
This standard applies to all commercial development plans submitted after June 1, 2010.

Water Harvesting Plan is required.
02/05/2019 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed After reviewing the Dunkin Donuts site plan, and notes, I noticed there is a 6" fire hydrant at the SW corner of the site. Normally commercial establishments require 8" fire hydrants. If the fire department is ok with a slightly less than 1,000 gpm flow from this hydrant to satisfy commercial fire flow requirements then it may be ok to leave this existing hydrant as is. However, the site plan is showing a proposed monument sign near the existing fire hydrant location. Tucson Water SD 500 has specific standards for placement of fire hydrants. In this case the monument sign can not be placed within 5 feet of an existing or proposed fire hydrant (see note on page 2 of 8 of SD 500). See web link below.

https://www.tucsonaz.gov/files/water/docs/StandardSpecsDetails/SD-500.pdf

Thanks.
Paul Baughman, PE, CFM
Civil Engineer
Tucson Water
310 W Alameda St.
Tucson, AZ 85701
520-837-2048
02/05/2019 MARTIN BROWN COT NON-DSD FIRE Approved
02/07/2019 JOHN VAN WINKLE ENGINEERING REVIEW Completed T19PRE0016

1) Sidewalks will need to be provided along Grant Rd and Flowing Wells Rd along with pedestrian circulation to both
2) Trash enclosure location appears to interfere with PAAL width
3) Confirm with TDOT the placement of the entry way which is close to the Flowing Wells Rd/Grant Rd Intersection

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
02/11/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting (T19PRE0016)
Address: 2420 N Flowing Wells Rd
Parcel(s): 107-07-019A
Zoning: I-1
Existing Use: Vacant, Cell Tower on site
Proposed Use: Commercial - Food Service

TRANSMITTAL DATE: February 11, 2019

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a Commercial - Food Services use, which is permitted in the I-1 zone.
3. The maximum height for nonresidential buildings is 75 feet. Interior perimeter yard setbacks are 0 feet.
4. The site is located on two designated Major Streets & Routes, Flowing Wells and Grant. The required street setback on each street is 21' or the height of the structure, as measured from the back of future curb.
5. Parking is required for a total of 22 spaces, with 1 accessible space required. If providing more than 25 parking spaces, 2 accessible spaces are required.
6. Both short-term and long-term bicycle parking will be required to be provided on site.
7. At least one sidewalk is required to a project from each street on which the project has frontage. The sidewalk should be located to minimize any conflict with vehicular access to the project.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
02/14/2019 JVWINKL1 COT NON-DSD TRAFFIC Completed