Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T19PRE0010
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0010
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Possible rezoning, conditions of annexation may apply. Access may be an issue.
01/30/2019 MASHFOR1 COT NON-DSD FIRE Approved Please provide hydrant location/access to water per TFD and road width
01/30/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC TRANSMITTAL

FROM: Elisa Hamblin, AICP
Principal Planner
PDSD Zoning Review Section

PROJECT: Thursday Pre-submittal 1/31/19 (T19PRE0010)
Annexation and Subdivision, 8882 E Placita Rio De Vidrio (Parcel 114-28-0250)

TRANSMITTAL DATE: 1/30/19

The following comments are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:
1. Annexation to the City of Tucson is required for the proposed subdivision. Additional information on annexation can be found online at: https://www.tucsonaz.gov/annexation/annexation-join-city-tucson. Please contact Mike Czechowski, Annexation Project Manager at Mike.Czechowski@Tucsonaz.gov.
2. Additional information is needed regarding the proposed zoning and potential subdivision design and layout.
3. If proposing an RX-1 zone, similar to adjacent properties, the minimum lot size is 36,000 square feet with 20' setbacks.
4. A Development Package (Tentative Plat) and Final Plat will be required for the proposed subdivision.
5. In order to gain access to the project site, the existing plat for Ghost River Ranch will need to be replatted. This may impact the HOA and CC&Rs.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966.
01/30/2019 JOHN VAN WINKLE ENGINEERING REVIEW Completed T19PRE0010

1) Development within the 100 year flood plain would have to show no adverse impact to surrounding area. If the floodplain delineation is being changed a LOMC would need to be submitted and approved by FEMA
2) An all-weather access route crossing the Indian Hills Wash would be required
3) 100 year regulatory flood plain and riparian area delineation would need to be shown
4) Erosion hazard setbacks for all regulatory discharges
5) Full street development to Bear Canyon Rd
6) Impact on Ghost River Ranch CC&R's due to the loss of lots 11 and 12
7) Maximum length of Dead End Street is 1200' assuming street has proper width and turn around; first 600' requires 36' of pavement width. TSM section 10-01.6.2
8) Check with TFD if secondary access is required

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
01/31/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed January 31, 2019
Address - 8882 E Placita Rio De Vidrio
T19PRE0010
TDOT Reviewer - Zelin Canchola

TDOT has no adverse comments or recommendations.
02/04/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Okay to Submit Notice: T19PRE0010
Project Description: SITE/PLAT/ANNEX - PARKER FAMILY - GHOST RIVER RANCH
Prior to submitting a development package, view the review details on www.tucsonaz.gov/pro, search by activity number.

Submit an application, plan set, and any documents requested in the review details per submittal requirements.

Thank you,
Alexandra Hines, AICP
Lead Planner at Planning and Development Services, City of Tucson
201 N Stone Ave 1st Floor, Tucson, AZ 85701
(520) 837-6975 - alexandra.hines@tucsonaz.gov
02/04/2019 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed