Plan Number: T19PRE0008
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T19PRE0008
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/23/2019 MASHFOR1 COT NON-DSD FIRE Completed Fire Requirements based on Occupancy Type/Usage:

903.2.9 Group S-1. An Automatic Sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where one of the following conditions exist:

1. A Group S-1 fire area exceeds 12,000 sqft

3. The Group S-1 fire areas on all floors, including any mezzanines, exceeds 24,000 sqft

**Unknown
5. A Group S-1 occupancy used for storage of upholstered furniture or mattresses exceeds 2,500 sqft
01/24/2019 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP
Principal Planner

PROJECT: Thursday Pre-submittal meeting 1/31/19 (T19PRE0008)
Address: 1760 W Irvington Rd
Parcel(s): 13711425E
Zoning: C-1
Existing Use: Vacant
Proposed Use: Personal Storage

TRANSMITTAL DATE: 1/24/19

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. At least one sidewalk is required to a project from each street on which the project has frontage. The sidewalk should be located to minimize any conflict with vehicular access to the project.
3. A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located.
4. The parking requirement is as follows: 1 space per 4,000 sq. ft. GFA, if storage units do not have direct vehicular access, and a minimum of 2 spaces for any associated office. A 122,685 square foot building would require 31 spaces plus 2 for the office.
5. The maximum building height in the C-1 zone is 30'. Setbacks on interior property lines are 0'. The setback from Irvington Rd is 21' or the height of the structure, as measured from back of future curb. It appears Irvington is at its full right-of-way width.
6. A total of 2 short-term bicycle parking spaces are required for Personal Storage uses. Long-term bicycle parking is not required.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
01/24/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Development Package is required for all site plans and tentative plats submitted to PDSD for review.
Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.

A separate Water Harvesting Implementation Plan shall be submitted with all applications for new commercial developments where landscaping is required. The plan shall detail the landscape water demand and the harvested water supply needed to meet 50 percent of landscape demand.

A separate Native Plant Preservation Plan shall be submitted for all new commercial development proposed in the City of Tucson
01/28/2019 LOREN MAKUS ENGINEERING REVIEW Completed Site is within a balanced basin. Balanced basin retention and detention are required.
Site is adjacent to a Pima County RFCD facility. Development package will need to be reviewed by the district.
01/31/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed January 31, 2019
Address - 1760 W Irvington
Storage Facility
Reviewer - Zelin Canchola

TDOT has no adverse comments. Development standards will apply during review process.
02/04/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Okay to Submit Notice: T19PRE0008
Project Description: SITE - SUN VALLEY, LLC SELF STORAGE
Prior to submitting a development package, view the review details on www.tucsonaz.gov/pro, search by activity number above.

Submit an application, plan set, and any documents requested in the review details per submittal requirements.

Thank you,
Alexandra Hines, AICP
Lead Planner at Planning and Development Services, City of Tucson
201 N Stone Ave 1st Floor, Tucson, AZ 85701
(520) 837-6975 - alexandra.hines@tucsonaz.gov