01/14/2019 MARTIN BROWN COT NON-DSD FIRE Reqs Change Fire department access, by definition, is a 20' wide paved road. Lots deeper than 150' from the road shall be supplied with an approved turnaround. All dwellings will need a residential sprinkler system due to distance from fire hydrants.
01/15/2019 ELISA HAMBLIN ZONING REVIEW Approved CDRC TRANSMITTAL

FROM: Elisa Hamblin, AICP
Principal Planner
PDSD Zoning Review Section

PROJECT: Thursday Pre-submittal 1/17/19
Tentative Plat - 4 lots
9161 E Magdalena Rd

TRANSMITTAL DATE: 1/15/19

COMMENTS: The following comments are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

1. The proposed tentative plat (development package) is for 4 lots, all with access to Magdalena Rd. The submittal appears to be in conformance with the rezoning approved preliminary development plan.

2. A supplemental site plan of the entire site is required with submittal of the final plat. Assure that compliance with the zoning development criteria can be met for each lot. It appears existing structures on lot 4 would not meet minimum setbacks. A Design Development Option (DDO) approval must be obtained for the reduced setback and will be required prior to final approval of the plat. If a setback reduction is desired on the other lots, please contact Mark Castro to confirm applicability.

3. Be aware that all new homes are to be designed to comply with the "Inclusive Home Design Ordinance, City of Tucson Ordinance 104631".

4. The applicant / Owner should be aware that the water department has specific regulations related to placement of meters and requirements for direct access to street frontage. Contact the Tucson Water Department to assure that the design as proposed will work for placement of the water meters.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966.
01/15/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change 7.7. NATIVE PLANT PRESERVATION
7.7.3. APPLICABILITY
The provisions of this section apply to the following:
1. Single-family residential development on lots recorded after March 24, 1997
NPP plan will be required along with tentative plat or with development of each lot.
SECTION 4-02.0.0: FLOODPLAIN, WASH AND ERZ STANDARDS
Encroachment in Regulated Areas
If the project proposes encroachment within the regulated areas, it shall conform to the following.
1. Environmental Resource Report. Applicants are required to submit an Environmental Resource Report as defined in Section 11.4.6 of the UDC.
01/15/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved No adverse comments or concerns. Technical standrds will apply
01/16/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change T19PRE0003

1) Access easements must demonstrate all weather access per section 11.2 of the City of Tucson Standards Manual for Drainage Design and Floodplain Management
2) Clarify if it is intended for Tucson Water to supply the proposed development. If yes, then Tucson Water requires property frontage to provide service

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
01/22/2019 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Completed Okay to Submit Notice: T19PRE0003
Project Description: TENT PLAT - PEARSON ESTATES, LOTS 1-4
Prior to submitting, view the meeting comments on www.tucsonaz.gov/pro, search by activity number.

Submit an application, plat, title report, and any documents requested in the meeting comments.

Thank you,
Alexandra Hines, AICP
Lead Planner at Planning and Development Services, City of Tucson
201 N Stone Ave 1st Floor, Tucson, AZ 85701
(520) 837-6975 - alexandra.hines@tucsonaz.gov