Plan Number: T19PI00021
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T19PI00021
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2019 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change Date - November 19, 2019
Project Park Avenue at Tucson "Market Place Turn Lane Improvements.
Reviewer - Zelin Canchola

The following requires change:

1. Sheet 10 of 33. Add second "Only/right turn lan sign at thedriveway.

2. Sheet 11 of 33. Add second "Only/right turn lane sign at the intersection.

Change these bottom plaques to "Public Buses Exempt"
11/27/2019 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Approved
11/27/2019 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
11/27/2019 RICHARD LEIGH DOT PERMITS & CODES REVIEW Approved
11/27/2019 ERNIE ENCINAS DOT_ELEC REVIEW Reqs Change Please see redline drawings
11/27/2019 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
11/27/2019 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
11/27/2019 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review
12/04/2019 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change Reviewer:
David Marhefka
da’-vid mär-hef’-ka
Landscape Architect
City of Tucson
Department of Transportation (o) 520-837-6618
(m) 520-403-5074



TDOT Landscape Comments:
1. There is existing vegetation and City maintained irrigation in the median that is sleeved in from the south. Please add the vegetation shown on the plans in the median but coordinate with City on using existing irrigation. There is no need to provide irrigation from west across Park to the median.
2. Move the Agave Americana, the Red Bird of Paradise out of the SVT north of the intersection. These will be too large at mature size.
3. Make sure that the above plants are also located far enough from walk ways and curbs that they will not impeded pedestrian and vehicular traffic at mature size.
4. Include the following notes on the Landscape Plans:
City of Tucson
Department of Transportation
Standard Notes for Planting in ROW

1. It is the owner’s responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Unified Development Code (UDC) Technical Standards Manual Section 10.
2. It is the owner responsibility to keep a 5’ wide by 7’ tall clear pedestrian access open across the entire property.
3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15’ high clear zone over the travel lane.
4. Final plant locations must be in compliance with all utility setback requirements.
5. The owner understands that if the City of Tucson Transportation Department or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair.
6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities.
7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property. (excluding water meter)
8. Contractor to obtain a Right Of Way permit prior to construction within the right-of-way.

City of Tucson
Department of Transportation
Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way
1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways
2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way.
3. The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811 and become an Arizona 811 Blue Stake Inc. member.
4. Minimize the number of roadway crossings.
5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting.
6. Irrigation lines shall be placed in ductile iron sleeves.
7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT.
8. HDPE continuous line (no joints under the pavement)
9. Irrigation lines shall have a minimum of thirty (30) inches of cover.
10. Detectable marking tape shall be installed.
11. Curb shall be marked/stamped with “IS” (Irrigation System) and/or placard at back of curb.
12/13/2019 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
12/13/2019 CRAIG SALTZMAN DOT ENGINEERING REVIEW Denied 1. Add Plan Number I-2019- 038 to all sheets.
2. Add PIA Number T19PI00021 top center of cover sheet with project title.
3. Provide curve data, in a table format, for proposed roadway.
Revise vertical profile, include stations, elevations, and slopes. Sheet 14 of 33 remove General Note: "Profiles are for informational…improvements."
4. Sheet 22 of 33, Catch basins show leader lines to center of sump. Per PAG Standard Detail 308, "The catch basin stationing is located at the center of the sump".
5. Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Jan14z.pdf
6. Include the following paving notes or revise per the following:
o Drainage pipe shall conform to PAG SSPI Section 501or as directed by the engineer.
o Pipe bedding shall conform to PAG Standard Detail 108.
o Aggregate Base Course shall conform to PAG SSPI Section 303
o Asphaltic Concrete shall conform to COT City Mix. (Indicate Mix Type)
o All concrete shall conform to PAG SSPI Section 1006, Class S, 3,000 PSI compressive strength at 28 days, unless otherwise specified.
o Pavement Section Design documentation, are in accordance to the approved Geotechnical Report,
Report Name and Firm Name, Project Number.
o All Drainage Infrastructures, indicated on the plans, are in accordance to the approved Drainage
Report approved by Development Services Department.
o Contractor shall obtain all other permits as required by Local, State and Federal requirements.
o Signage and striping should be coordinated with Traffic Engineering and installed at no expense to the public. Call Traffic Engineering at 791-4259 prior to the installation or removal of striping and signage.
o Upon commencement of work, traffic control devices shall be posted and maintained by the contractor until such time as the work is completed. All warning signs barricades etc. shall be in accordance with the manual on uniform traffic control devices adopted by the State of Arizona pursuant to A.R.S. 28-650. Contact Traffic Engineering, (520-791-4259), 48-hours prior to placing or removing any said traffic control devices.
o Contractor shall call Blue Stake as mandated by the Arizona Revised Statutes at 1-800-782-5348 before any construction begins to verify location of existing utilities shown or not shown. Existing utility locations shown hereon are only approximate. It is the contractor's responsibility to confirm horizontal and vertical location of all utilities without damaging same. Damaged utilities shall be repaired at no expense to the City.
o The contractor shall contact and/or coordinate any work with COT Streets & Traffic Maintenance Division, Electric Shop (520-791-3154) prior to relocation or placement of any street lighting or traffic facilities. Contact Gabriel Rascon at (520- 791-3154) for street lighting/traffic signal plan review.
o The contractor shall comply with all applicable Occupational Safety and Health Administration regulations.
o Floodplain Use Permit No. , has been issued by Development Services Department for work impacting City and FEMA Floodplains.
12/13/2019 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed