Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T19PI00021
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/19/2019 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | Date - November 19, 2019 Project Park Avenue at Tucson "Market Place Turn Lane Improvements. Reviewer - Zelin Canchola The following requires change: 1. Sheet 10 of 33. Add second "Only/right turn lan sign at thedriveway. 2. Sheet 11 of 33. Add second "Only/right turn lane sign at the intersection. Change these bottom plaques to "Public Buses Exempt" |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Approved | |
| 11/27/2019 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 11/27/2019 | RICHARD LEIGH | DOT PERMITS & CODES | REVIEW | Approved | |
| 11/27/2019 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Reqs Change | Please see redline drawings |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
| 11/27/2019 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review | |
| 12/04/2019 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Reqs Change | Reviewer: David Marhefka da’-vid mär-hef’-ka Landscape Architect City of Tucson Department of Transportation (o) 520-837-6618 (m) 520-403-5074 TDOT Landscape Comments: 1. There is existing vegetation and City maintained irrigation in the median that is sleeved in from the south. Please add the vegetation shown on the plans in the median but coordinate with City on using existing irrigation. There is no need to provide irrigation from west across Park to the median. 2. Move the Agave Americana, the Red Bird of Paradise out of the SVT north of the intersection. These will be too large at mature size. 3. Make sure that the above plants are also located far enough from walk ways and curbs that they will not impeded pedestrian and vehicular traffic at mature size. 4. Include the following notes on the Landscape Plans: City of Tucson Department of Transportation Standard Notes for Planting in ROW 1. It is the owner’s responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Unified Development Code (UDC) Technical Standards Manual Section 10. 2. It is the owner responsibility to keep a 5’ wide by 7’ tall clear pedestrian access open across the entire property. 3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15’ high clear zone over the travel lane. 4. Final plant locations must be in compliance with all utility setback requirements. 5. The owner understands that if the City of Tucson Transportation Department or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair. 6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities. 7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property. (excluding water meter) 8. Contractor to obtain a Right Of Way permit prior to construction within the right-of-way. City of Tucson Department of Transportation Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way 1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways 2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way. 3. The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811 and become an Arizona 811 Blue Stake Inc. member. 4. Minimize the number of roadway crossings. 5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting. 6. Irrigation lines shall be placed in ductile iron sleeves. 7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT. 8. HDPE continuous line (no joints under the pavement) 9. Irrigation lines shall have a minimum of thirty (30) inches of cover. 10. Detectable marking tape shall be installed. 11. Curb shall be marked/stamped with “IS” (Irrigation System) and/or placard at back of curb. |
| 12/13/2019 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 12/13/2019 | CRAIG SALTZMAN | DOT ENGINEERING | REVIEW | Denied | 1. Add Plan Number I-2019- 038 to all sheets. 2. Add PIA Number T19PI00021 top center of cover sheet with project title. 3. Provide curve data, in a table format, for proposed roadway. Revise vertical profile, include stations, elevations, and slopes. Sheet 14 of 33 remove General Note: "Profiles are for informational…improvements." 4. Sheet 22 of 33, Catch basins show leader lines to center of sump. Per PAG Standard Detail 308, "The catch basin stationing is located at the center of the sump". 5. Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Jan14z.pdf 6. Include the following paving notes or revise per the following: o Drainage pipe shall conform to PAG SSPI Section 501or as directed by the engineer. o Pipe bedding shall conform to PAG Standard Detail 108. o Aggregate Base Course shall conform to PAG SSPI Section 303 o Asphaltic Concrete shall conform to COT City Mix. (Indicate Mix Type) o All concrete shall conform to PAG SSPI Section 1006, Class S, 3,000 PSI compressive strength at 28 days, unless otherwise specified. o Pavement Section Design documentation, are in accordance to the approved Geotechnical Report, Report Name and Firm Name, Project Number. o All Drainage Infrastructures, indicated on the plans, are in accordance to the approved Drainage Report approved by Development Services Department. o Contractor shall obtain all other permits as required by Local, State and Federal requirements. o Signage and striping should be coordinated with Traffic Engineering and installed at no expense to the public. Call Traffic Engineering at 791-4259 prior to the installation or removal of striping and signage. o Upon commencement of work, traffic control devices shall be posted and maintained by the contractor until such time as the work is completed. All warning signs barricades etc. shall be in accordance with the manual on uniform traffic control devices adopted by the State of Arizona pursuant to A.R.S. 28-650. Contact Traffic Engineering, (520-791-4259), 48-hours prior to placing or removing any said traffic control devices. o Contractor shall call Blue Stake as mandated by the Arizona Revised Statutes at 1-800-782-5348 before any construction begins to verify location of existing utilities shown or not shown. Existing utility locations shown hereon are only approximate. It is the contractor's responsibility to confirm horizontal and vertical location of all utilities without damaging same. Damaged utilities shall be repaired at no expense to the City. o The contractor shall contact and/or coordinate any work with COT Streets & Traffic Maintenance Division, Electric Shop (520-791-3154) prior to relocation or placement of any street lighting or traffic facilities. Contact Gabriel Rascon at (520- 791-3154) for street lighting/traffic signal plan review. o The contractor shall comply with all applicable Occupational Safety and Health Administration regulations. o Floodplain Use Permit No. , has been issued by Development Services Department for work impacting City and FEMA Floodplains. |
| 12/13/2019 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |