Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T19PI00011
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2019 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | August 9, 2019 SUBJECT: T19PI00011 Bella Tierra PROJECT REVIEWER: Zelin Canchola, TDOT Review Section RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. The proposed plan requires the following change: Signs: 1. Add End of road markers at the end of pavement on Limderbrook Dr. The existing object markers, type 3 (MUTCD) are used for obstructions adjacent to the roadway. MUTCD Section 2C.66 Object Markers for Ends of Roadway states a Type 4 (Red Square) shall be used for end of roadways. 2. If adding pavement on Linderbrook eliminate keynote 14. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 09/17/2019 | CRAIG SALTZMAN | DOT ENGINEERING | REVIEW | Denied | 1) Sht. 2 of 17; General Notes , note 3. ADD" City of Tucson" before "Mix # 2". 2) Sht. 2 of 17; General Notes, note 13. Correct the spelling of David Marhefka name. 3) Sht. 3 of 17; Catch Basin Details, Stations and elevations use Engineering Dimensions (Feet and tenths of a foot). Dimension of the structure use Carpenter Dimensions (feet and inches). Example 1.5" = 1'-6" and 0.5' =0'-6". 4) Sht. 4 of 17: Detail Basin Detail see note 3 above. |
| 09/18/2019 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 09/18/2019 | RICHARD LEIGH | DOT PERMITS & CODES | REVIEW | Approved | |
| 09/18/2019 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |