Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T19PI00011
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 04/10/2019 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 04/16/2019 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | Streets irrigation and landscape maintenance does not have any concerns at this location. Paul Rosenboom |
| 05/08/2019 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | May 8, 2019 SUBJECT: T19PI00011 MLK Jr Way PROJECT REVIEWER: Zelin Canchola, TDOT Review Section RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. The proposed plan requires the following change: 1. Identify key note 5 on the plan sheets 2. Add new striping quantities 3. No striping on Linderbrook Drive required. 4. Add End of road markers at the end of pavement on Limderbrook Dr 5. Add diagonal striping within gore area on Camino Seco. 6. New pavement required to accommodate new striping on Camino Seco. (obliteration may not be possible with existing pavement's condition) 7. If adding pavement on Linderbrook eliminate keynote 14 If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 05/15/2019 | CSALTZM1 | DOT ENGINEERING | REVIEW | Denied | 1) Sht. 1 of 17 ; Top center of sheet under Title add PI No. T19PI00011 2) Sht. 1 0f 17; Add recorded sequence to cover Sheet (plat, grading plan, etc.) 3) All sheets add to title block Plan No. I-2019-007. 4) Sht. 2 of 17; General Notes , note 3. Remove" P.A.G. SSPI Section 406" and replace w/ City of Tucson Mix # 2. 5) Sht. 2 of 17; General Notes, note 13. Remove "Gary Wittwer@400-2645" and replace with" David Marhefka @ 403-5074". 6) Sht. 3 of 17; Add Structural Pavement Section. 7) Sht. 3 of 17; Catch Basin Details, Stations and elevations use Engineering Dimensions (Feet and tenths of a foot). Dimension of the structure use Carpenter Dimensions (feet and inches). 8) Sht. 4 of 17: Detail Basin Detail see note 7 above. 9) Sht. 5 of 17; Thickened Pavement Edge Detail, Change 11Inches to 12inches. Change dimension line for only the thickness of the thickened edge of the new AC pavement. 10) Sht. 6 of 17; Maintain full pavement section from Station 6+47.62 to Station 10+00 match line between Phase 1A and 1B. Include all drainage structures required for full width section. 11) Change Linderbrook Dr Tapered Section to full pavement section per note 10. |
| 05/20/2019 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 05/21/2019 | RICHARD LEIGH | DOT PERMITS & CODES | REVIEW | Needs Review | |
| 05/21/2019 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 05/21/2019 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |