Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T19CM09370
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/02/2020 | RMCCOY1 | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
01/02/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
01/02/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the waste and vent diagram with the plumbing plan. A 4" building drain requires a 4" cleanout. [Initial comment: Clarify the arrangement of the fixture drains (i.e. provide a waste and vent diagram).] 2. The horizontal drains from P4, P3, and P1H cannot connect to the vent for P2H. [Initial comment: A common vent can accommodate only two fixtures.] |