Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T19CM09349
Parcel: 101211500

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T19CM09349
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/20/2019 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T19CM09349
5058 N Wild Life Place
New SFR
Residential (1st Review)

TRANSMITTAL DATE: December 20, 2019

The porch addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the RX-1 zone. A single-family residence is a permitted use in this zone.

1. The zoning listed on the plan is not correct and should be listed as RX-1. Also provide the zoning for all parcels adjacent to this parcel.

2. Clarify what the distances that you list under the zoning are. Are they required perimeter yard setbacks or the actual setback distance.

3. The "BUILDING HEIGHT LIMIT" listed is not correct and should be 30'

4. Provide a copy of the approved model plan with the next submittal so that heights can be verified.

5. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
12/23/2019 LOREN MAKUS ENGINEERING REVIEW Needs Review Grading Development Package is required.
12/27/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T19CM09349
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the location of utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
12/30/2019 SBORZAK1 NPPO REVIEW Completed