Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW - COMMERCIAL
Permit Number - T19CM09198
Review Name: 3RD PARTY REVIEW - COMMERCIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/15/2020 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T19CM09198 - In-Out-Burger - New Food Service Building Plan Review (1st Review) / Relate to DP16-0044 1100 W Irvington / PAD-29 TRANSMITTAL DATE: January 15th, 2020 DUE DATE: January 22nd, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Zoning has reviewed the building plans for compliance with the approved development package. Zoning cannot approve the building plans until the PDSD Commercial Plans reviewers have approved the building plans. 2. COMMENT: The building area shown on the building plans (3,879 sf) does not match that of the approved DP (4,516 sf), Revise the floor area on the next submittal to provide a consistent building area. 3. COMMENT: Zoning will review the building plans on the next submittal as it relates to the zoning review purview and compare the building plan footprint, building height, and square footage and location to ensure consistency with the DP. 4. COMMENT: Once the plans have been reviewed and approved by PDSD Commercial Plan Reviewers and zoning has verified consistency with the DP, the building plans can be approved by zoning. If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.Monshizadeh@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov |
| 01/17/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 01/23/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 01/27/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | 1) Please clarify which development package is being used for this project. If DP16-044 is being used please remove sheets C1-LPD.1 from the building plans. If C1-LPD.1 are being used a seperate Development Package submittal and review is required 2) Ensure that roof drains, from the new building, scupper underneath sidewalks as needed. Reference COT Technical Standards Manual (TSM) section 7-01.4.1.e. Coordinate with the Development Package John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 03/16/2020 | STANTEC | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/16/2020 | AMARTIN1 | OUT TO CUSTOMER | Completed |