Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T19CM08412
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/05/2020 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: Detached Solar Structure (Residential Use) Building Plan (1st Review) 742 W NEBRASKA ST T19CM08412- R-2 Zoning TRANSMITTAL DATE: February 5, 2020 DUE DATE: February 11, 2020 ***Address comment 2 and resubmit for review. COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Zoning has reviewed the plan and cannot approve at this time. Please address the following comments. 02. COMMENT: The proposed solar structure has been located along the west side of the dwelling from the previous proposed front location. As noted in the previous comment the minimum building setbacks to the side yard are the greatest of 6 feet or 2/3 the height of the structure side facing the west property line in this case. It is assumed that the height of 7' is the side facing the west line based on the cross section drawing. Per the site drawing the edge of the solar structure is to be located 4'-2" from the property line. Unless the structure can be placed 6 feet from the property line the owner must obtain a setback waiver from the adjacent owner. A statement can be added to the site plan whereby the adjacent owner acknowledges that he has no objection to the structure being constructed at 4'-2" as depicted on the site plan. See statement that needs to be added to the site plan. Staff will verify the property "owner" at the next review. The adjacent owner's setback waiver statement must be added to the site plan. The following statement can be used. "My Name is (Owners name) __________________ and I am the owner of the property located at (property address) __________. I have reviewed the site plan and I have no objection to the structure being located or constructed (distance) ______ from the property line as depicted on the site plan". Signature: _____________ Date: ________________ Previous Comment 3: The proposed solar structure is not permitted to extend beyond the front elevation of the existing dwelling unless approved through a board of adjustment variance or the structure is attached to the dwelling. The attachment must be a minimum of five foot wide permanent connection to the dwelling. Include with the next plan submittal, dimensioned elevation drawings demonstrating the connection and heights of the solar structure. (Keep in mind that the building setbacks are the greatest of 6 feet or 2/3rds the height of the structure. If you have any questions about this transmittal, Contact David Rivera at (520) 837-4957 or by email David.rivera@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 02/13/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | Engineering can approve the building plans once all outstanding zoning comments have been addressed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/20/2020 | TWEIDEM1 | APPROVAL SHELF | Completed |
| 03/20/2020 | TWEIDEM1 | OUT TO CUSTOMER | Completed |
| 03/20/2020 | TWEIDEM1 | REJECT SHELF | Completed |